background image

Installation of water supply

Installation Drawing (Integrated Ice Machine)

4

1. Ice machine must use room-temperature drinkable water.
2. Water pressure must be controlled between 0.15 MPa and 0.3 MPa.

3. Inlet hose with 3/4” internal thread (20mm) and 1/2” internal thread (15mm) joints

at both ends,which has a stone guire seal washer so that there is no need to wrap

raw tape.

4. Filter is equipped with filter element, use a wrench to unscrew the filter element

before using, take out the filter element, tear off the packaging film of the filter 

element, install back as it is and tighten it. A new filter element should be replaced 

every six months.

5.The direction of inlet and outlet is marked on the filter cover. Please pay attention

to the installation. 

6.Connect the 3/4’ joint to the machine inlet (white 3/4’ male thread)1/2 joint to the 

water supply pipe.

7.For water cooling ice machine, the machine added two 3/4’ pipe joint at the place

of in and out, which color is black to distinguish the ice making inlet.

8.The ice machine drains water by gravity, so it is necessary to ensure adequate

slope and drop.

Drain Pipeline

Black

Power

Filter

Ice making water inlet

white

Before using filter,must take out 

the filter element, tear off the 

packaging film of the filter 

element, install it and tighten it.

Summary of Contents for IC-35BWA

Page 1: ...USER MANUAL Ice Machines IC 35BWA IC 50A IC 50BWA...

Page 2: ...3 4 5 5 6 7 8 9 Receiving and Inspection Structure and Interface Name Foot Mounting Installation of water supply Electrical Safety Precautions Adjust Ice Thickness Maintenance Daily Cautions Fault Co...

Page 3: ...and safe 1 The packing of the machine is in good condition 2 Is the machine model constent with your purchase order 3 In apparent good condition 4 whether all assembly part are complete 5 whether Mac...

Page 4: ...Door of Ice Bin Decorating Plate Wcrking Status Indicator Supporting Feet Nodel Label Drain Pipeline Black Power Filter Ice making water inlet white Structure and Interface Name 2...

Page 5: ...ce machine is not suitable for outdoor the normal operating ambient temperature is 10 6 Ice machine should not be installed in where is no sewer and it is forbidden to put together with high temperatu...

Page 6: ...nstall back as it is and tighten it A new filter element should be replaced every six months 5 The direction of inlet and outlet is marked on the filter cover Please pay attention to the installation...

Page 7: ...e machine otherwise it may cause short circuit electric leakage and other faults 7 If it needs be stopped working for a long time it should be switched on and run 4 to 6 hours every two months 1 Do no...

Page 8: ...mber displayed on the digital tube increases or decreases by 1 that means the thickness of the ice increases or decreases by 1 minute the adjustment range is 0 35 minutes If the button is not pressed...

Page 9: ...ts E05 Water shortage fault 1 There is on water in the inlet pipe 2 Low water pressure in the inlet pipe 3 The inlet valve damaged 4 The tank is leaking Check related parts E06 Pressure overruns 1 Exc...

Page 10: ...lso be forced into the ice shedding process 3 Ice shedding Cyele up to 40 minutes During the Ice shedding process the ice grid is heated and the surface of ice at where sticking to ice grid become mel...

Page 11: ...nk and ice bin can be cleaned with water pipes but do not have excessive water pressure Do not directly flush the water pump and upper part of ice grid to prevent the circuit flooding 5 Condenser of a...

Page 12: ...rketed globally by TRUFROST COOLING PRIVATE LIMITED 1215 12th Floor Tower B Emaar Digital Greens Golf Course Extn Road Sector 61 Gurugram 122102 India T 91 7303166766 info trufrost com www trufrost co...