FULLY TOUCH SCREEN SERIES

9 TERMINAL POWER BOX

*wiring is subject to change without notice based on addons

PRODUCT DIMENSION

6

NOTE:

♦ The thermostat is high voltage input, please do wiring with technician.

♦ If the thermostat was burned by accidently, please do not wiring it again by yourself, try to check it with a professional technician or contact    
with our manufacturer.

WIRING DIAGRAM

NO

1

L

LIVE LINE IN

3

FH

HIGH SPEED FAN 

4

FM

MEDIUM SPEED FAN 

2

DESCRIPTION

5

FL

LOW SPEED FAN 

6

N

NEUTRAL IN

7

COM

COM FOR MODULATING VALVE & 
EXTERNAL SENSOR/ KEY CARD

8

AO

ANALOG OUTPUT 0-10VDC

9

AI / DI

EXTERNAL SENSOR/KEY CARD

TERMINALS

NO

1

R

24 V ACTIVE

3

FH

HIGH SPEED FAN

LINE

220V LINE FOR FAN

4

FM

MEDIUM SPEED FAN

2

DESCRIPTION

5

FL

LOW SPEED FAN

6

C

24V NEUTRAL

7

AO

ANALOG OUTPUT 0-10VDC

8

COM

COM FOR MODULATING VALVE & 
EXTERNAL SENSOR /KEY CARD

9

AI / DI

EXTERNAL SENSOR / KEY CARD

TERMINALS

Fan

TX986ML220-V2E

(0-10VDC)

AI (External Sensor)

COM

(0-10VDC)

Fan

85-240VAC

TX986ML220-V2K

DI(key card)

COM

Fan

24VAC

TX986ML024-V2E

(0-10VDC)

AI (External Sensor)

COM

Fan

24VAC

TX986ML024-V2K

(0-10VDC)

DI(key card)

COM

Summary of Contents for TX986ML220-V2E

Page 1: ...and DX single stagecompressor units We introduce Bacnet and Modbus communication in this series Option of 9 terminals 13 terminals power box can occupy addons Like AO AI DO and DI as per convenience...

Page 2: ...e 4 pipe FCU Suitable Valve 2 line 3 line valve Relative Humidity 10 90 13 terminal power box fits in 86cm x 86 cm 9 terminal power box fits in 75cm x 75cm electrical junction box ORDERING PART NUMBER...

Page 3: ...ROGRAMMABLE ADJUSTING OF WEEKLY PROGRAMMABLE 3 Press and hold and for more than 5 seconds the icon of or will flash press to select manual or programmable press to confirm After selected programmable...

Page 4: ...ss to confirm Press and revise the values of the setting items press to confirm If you want to revise the other setting items please repeat above step b and c while setting press to exit the setting i...

Page 5: ...ACTUAL CONDITION 0 INTERNAL SENSOR BUILT IN 1 EXTERNAL SENSOR 0 5 WORKING DAYS A WEEK 1 6 WORKING DAYS A WEEK 2 7 WORKING DAYS A WEEK 3 CLOSE THE PROGRAM SCHEDULE PS IF YOU SELECTED 7 WORKING DAYS A W...

Page 6: ...2 DESCRIPTION 5 FL LOW SPEED FAN 6 N NEUTRAL IN 7 COM COM FOR MODULATING VALVE EXTERNAL SENSOR KEY CARD 8 AO ANALOG OUTPUT 0 10VDC 9 AI DI EXTERNAL SENSOR KEY CARD TERMINALS NO 1 R 24 V ACTIVE 3 FH H...

Page 7: ...ck plate on the junction box by screw driver Install the thermostat about 5 feet 1 5m above the floor in an area with good air circulation at average temperature Do not install in locations where the...