P.20
ON
ON turns the output on:
Reply: Status-OK
C³V00 ON<CR><LF>
OK<CR><LF>
OFF
OFF turns the output off:
Replay: Status-OK
C³V00 OFF<CR><LF>
OK<CR><LF>
Data Format CMD-L (C³V Series to PC)
Status-L (C³V Series to PC)
This field is the command code of this protocol.
Status
Function Description
Vcom
Reply voltage value of setting:
C³V00 L<CR><LF>
Vcom=20.00,Vout=1.35,Icom=3.500,Iout=0.000,Tspace=30.8,Relay=ON
<CR><LF>