5.4.1 RS485 Termination Resistor (120R) Installation & Wiring 
When installing, please connect a 120

Ω 

termination resistor to the “+/-“ terminals of 

the green terminal block of the final parallel unit of C³V Series. 
 

 

 
5.4.2 RS485 Address   
The RS485 address must be set from 1 to 32 and cannot duplicated. USB & RS232 
interface do not require set up as default value “0” is already factory preset.   
 
Refer to Chapter 4 for instructions on the RS485 address setup and query. 
 

Summary of Contents for C3V 2010

Page 1: ...C V Series 2010 4005 6003 Programmable DC Power Supply...

Page 2: ...s 3 Operation p 9 3 1 General 3 2 Description 3 3 Output Reading Mode Setting Mode 3 4 Switching between Two Modes 4 Keys Special Functions p 12 4 1 Normal Operations 4 2 Special Functions 4 3 Default...

Page 3: ...V Series 7 Automatic Fan Speed vs Temperature Control p 23 7 1 PWM Fan Speed Control 7 2 Over Temperature Protection OTP Alarm 8 C V Series Wiring and Connections p 24 8 1 All Connections 8 2 Special...

Page 4: ...chapters and on the product itself Indicates an imminently hazardous situation which if not avoided will result in death or serious injury Indicates a potentially hazardous situation which if not avo...

Page 5: ...lock the ventilation openings at the enclosure of the product Do not place any heavy objects on the product 1 3 3 Installation The product is constructed to Protection Class I Connect the product to a...

Page 6: ...that no harmful residual voltage remains at the terminals of bulk capacitors Replace the fuse only with the same amperage and voltage ratings to avoid risk of fire This is a Class A device which may...

Page 7: ...selection Up Down inputs confirmation 4 Up key Input increments 5 Down key Input decrements 6 V LED Green V denotes unit VOLT for meter display Lit state Meter display in Output Reading mode Blinking...

Page 8: ...Ground terminal negative terminal and positive terminal respectively 11 Model output ratings See 2 2 2 2 Models Output Ratings C V series consists of 3 models and ratings as listed below Model 2010 4...

Page 9: ...lay Meter Pressing the Enter key momentarily switches between different operation modes The V LED and A LED indicate the selected operation mode The CC LED indicates that the power supply currently be...

Page 10: ...as entered Setting Mode The V LED OR A LED AND the respective decimal point will be blinking on the 4 digit Display Meter Use the Up or Down keys to set the desired voltage or current Press the Enter...

Page 11: ...ng between Two Modes Press the Enter key for 3 seconds to switch between Output Reading Mode and Setting Mode This operation is especially useful for circuit experiments where frequent changes of V or...

Page 12: ...fer to the Display Meter on the panel Down key Momentary press gets least digit decrement Press and hold to get larger digit decrement more and faster decrement Please refer to the Display Meter on th...

Page 13: ...P 13 4 3 Default Output State ON OFF Output state when the unit is powered on JP7 on MCU card Default state at AC power on OPEN Output OFF SHORT Output ON Note User modification not recommended...

Page 14: ...e modified after delivery 5 1 Communication Data Rate Data rate 57600 N 8 1 Baud Rate 57600 Parity None Data Bit 8 Stop Bit 1 Flow Control None 5 2 C V Series with RS232 Interface Uses standard female...

Page 15: ...Connection with PC 5 3 C V Series with USB Interface USB Type B Connector as shown below 5 4 C V Series with RS485 Interface The RS485 address needs to be set up before communication Each C V Series m...

Page 16: ...e terminals of the green terminal block of the final parallel unit of C V Series 5 4 2 RS485 Address The RS485 address must be set from 1 to 32 and cannot duplicated USB RS232 interface do not require...

Page 17: ...ver sends messages till it receives the CMD from the PC 6 1 Communication between PC and C V Series As shown below PC sends CMD L C V Series replies Status L PC sends CMD VCOM C V Series replies Statu...

Page 18: ...rotocol If this code is correct C V Series will receive commands Every C V Series unit can be set with an address from 1 to 32 When using the RS485 interface you must set a unique address code for eac...

Page 19: ...cription L The L query returns all C V Series statuses Reply Status L C V00 L CR LF Vcom 20 00 Vout 1 35 Icom 3 500 Iout 0 000 Tspace 30 8 Relay ON CR LF SYS The SYS query returns the model and firmwa...

Page 20: ...Replay Status OK C V00 OFF CR LF OK CR LF Data Format CMD L C V Series to PC Status L C V Series to PC This field is the command code of this protocol Status Function Description Vcom Reply voltage v...

Page 21: ...ent value C V00 L CR LF Vcom 20 00 Vout 1 35 Icom 3 500 Iout 0 000 Tspace 30 8 Relay ON CR LF Relay Reply RELAY status C V00 L CR LF Vcom 20 00 Vout 1 35 Icom 3 500 Iout 0 000 Tspace 30 8 Relay ON CR...

Page 22: ...P 22 Status OK C V Series to PC Status OK Function Description OK Reply OK C V00 ON OK...

Page 23: ...ts the fan speed automatically This extends the fan lifespan and reduces mechanical noise when there is no output If the output current exceeds one half of the maximum current the fan will be set at f...

Page 24: ...ter To be connected and fixed at C V Connection with external cables AC input Rear panel IEC male IEC female cord Terminal board Y or O type terminal with wires DC output Front panel Banana jack Banan...

Page 25: ...following table suggests some applicable sizes for DC output lead wire where the maximum current and minimum DC resistance are considered Gauge Diameter mm Rated Current A meter AWG 12 2 06 26 005211...

Page 26: ...aphic illustrate the types of input output connection and communication interfaces on panels 1 Terminal board output 4 USB type B interface 2 Banana socket output 5 RS 485 interface 3 IEC AC input w o...

Page 27: ...g methods require clear ventilation paths Please keep the ventilation paths free of blockings and obstacles 9 1 Flat Mount Illustration for the flat mount and the associated ventilation flows Position...

Page 28: ...Mount Illustration for the erect mount and the associated ventilation flows Positioning reference for erect mounting Caution Using a screw longer than 7mm may penetrate the circuit board and cause pr...

Page 29: ...ent Amp 0 9 99A 0 5A 0 3 5A Power Watt 200W 200W 210W Line regulation CV mV 10mV 10mV 10mV CC mA 5mA 5mA 5mA Load regulation CV mV 10mV 10mV 10mV CC mA 5mA 5mA 5mA Ripple Noise 1 CV p p mV 30mVpp 30mV...

Page 30: ...es COMMUNICATION Interface only 1 option RS232 DB9 RS485 terminal block USB type B Protocol Data rate 57600 N 8 1 NORMS EMC EMISSION EN61000 3 2 3 EMC IMMUNITY EN61000 4 2 3 4 5 6 8 1 SAFETY EN60950 1...

Page 31: ...vvii output ratings 2010 0 20V 0 10A 4005 0 40V 0 5A 6003 0 60V 0 3 5A FT Front DC output terminals TB terminal board BN banana jack RT Rear AC input connections TB terminal board EC IEC male C Comm...

Reviews: