6
TRUE RESIDENTIAL
®
ELEC TRICAL SPECIFICATIONS
Do not, under any circumstances, cut or remove
the third (ground) prong from the power cord. For
personal safety, this appliance must be properly
grounded.
To minimize the depth of the cutout opening, the
electrical outlet must be positioned as shown below.
Outlet must be flush with wall.
Before your new unit is connected to a power supply,
check the incoming voltage with a volt meter. If
anything less than 100% of the rated voltage for
operation is noted, correct immediately.
The power cord of this appliance is equipped with
a 3-prong (grounding) plug which mates with a
standard 3-prong (grounding) wall outlet to minimize
the possibility of electric shock hazard from this
appliance. A 115V AC, 60 Hz, 15 amp circuit
breaker and electrical supply are required.
Each unit requires a dedicated circuit. Have the wall
outlet and circuit checked by a qualified electrician
to make sure the outlet is properly grounded.
If the outlet is a standard 2-prong outlet, it is your
personal responsibility and obligation to have it
replaced with the properly grounded 3 prong wall
outlet.
Do not use an extension cord or two prong adaptor.
Electrical ground is required on this appliance.
The unit should always be plugged into its own
individual electrical circuit, which has a voltage rating
that matches the rating plate. This provides the best
performance and also prevents overloading house
wiring circuits which could cause a fire hazard from
overheated wires. Never unplug your refrigerator by
pulling on the power cord. Always grip plug firmly
and pull straight out from the outlet.
Repair or replace immediately all power cords that
have become frayed or otherwise damaged. Do not
use a cord that shows cracks or abrasion damage
along its length or at either end. When moving the
refrigerator away from the wall, be careful not to roll
over or damage the power cord.
OUTDOOR USE
All True undercounter units are UL-rated for outdoor
use.
In regions that have high dewpoint/high humidity, it
is possible that you will see some condensation on
the glass and possibly around some of the gasket
seals. For best operation, it is recommended that
your True unit be stocked full with product.
To winterize your True unit, it is recommended once
the temperature reaches below 32ºF consistently that
products are removed from the unit, the unit is either
unplugged or turned OFF, and a cover is placed over
the unit.
Installation – For best operation, it is recommended
that your True unit is installed so that the countertop
of your outdoor kitchen/bar covers the door or drawer
gasket. Cutout opening should be a minimum of 24
inches deep and unit should be installed “flush”.
Please note that door/drawer gaskets do not provide
a water tight seal against the elements.
2"
2"
8"
Rear wall of cut out
Summary of Contents for TRUE RESIDENTIAL TBC-24-L-OG-B
Page 2: ...THANK YOU FOR YOUR PURCHASE ...
Page 29: ...27 15 INCH 24 INCH INSTALL GUIDE Back of drawer 8 7 6 24 INCH DRAWER OVERLAY PANEL ...
Page 57: ...55 15 INCH 24 INCH INSTALL GUIDE NOTES ...
Page 64: ...62 TRUE RESIDENTIAL S h e l v i n g A d j u s t m e n t 52 53 PRESERVE THE MOMENT ...
Page 66: ...64 TRUE RESIDENTIAL S t a c k i n g K i t I n s t r u c t i o n s 54 60 PRESERVE THE MOMENT ...
Page 80: ...78 TRUE RESIDENTIAL NOTES ...
Page 81: ...79 15 INCH 24 INCH INSTALL GUIDE NOTES ...
Page 82: ...80 TRUE RESIDENTIAL LINE NOTES ...
Page 83: ......