![True TBC-24-A Service Manual Download Page 57](http://html.mh-extra.com/html/true/tbc-24-a/tbc-24-a_service-manual_1175312057.webp)
5 3
15 & 24 INCH SERVICE MANUAL
FIGURE 1
FIGURE 2
Tape front door closed. Lean front of cabinet
against wall or something as stable. Cover
front of cabinet to keep from damaging
wall or cabinet. Remove rear cover. Rest
unit against the wall and remove the back
and bottom of the unit.
FIGURE 3
FIGURE 4
REPL ACING THE COMPRESSOR
Reclaim per EPA standards. Cut suction
line just above joint (figure 2). Rotate
suction line attached to compressor out of
the way. Disconnect liquid line.
Remove (4) 3/8” bolts from both left
and right of the bottom panel (figure
3). Insert a 2x2 to hold bottom down
(figure 4). Remove the pull pins located
on each bolt of the compressor legs. Pull
compressor up to clear bolts and pull out.
With compressor removed change drier.
Reinstall compressor in reverse order.
*A 50 0 MICRON VACUUM MUST BE PULLED AND CHA RGE WEIGHT BACK IN.