![True TBC-24-A Service Manual Download Page 36](http://html.mh-extra.com/html/true/tbc-24-a/tbc-24-a_service-manual_1175312036.webp)
32
TRUE RESIDENTIAL
®
T (F°)
Ω
14°
55. 3K
23°
42 . 3K
32 °
32 .6K
41°
25. 3K
50°
19.9K
59°
15.7K
68 °
12 . 5K
7 7 °
10K
86°
8K
95°
6. 5K
104°
5. 3K
EVAPOR ATOR SEC TION L AYOUT
EVAPORATOR FAN MOTOR
EVAPORATOR FAN MOTOR DRIVER
BLUE PROBE – DEFROST ASSIST PROBE
BLACK PROBE – CUT IN & CUT OUT
12V DC
120V AC
The evaporator fan motor driver is located directly next to the evaporator fan.
The motor driver will have 120V AC coming in and 12V DC going to the motor.
EVAPOR ATOR FAN DRIVER
PROBE VALUES
B VERSION