background image

 
 

 

 

TRUE SOURCE

 

     

User Manual

     

 

 

 
 

Alternating Air Mattress & Pump System   

 

 

   

 
 

Model

TS-105

 

 

 

 

 

 

 

UM-105-E-V1.0      Copyright © 2010 by TRUE SOURCE Technology Co., Ltd.   

 

Summary of Contents for TS-105

Page 1: ...TRUE SOURCE User Manual Alternating Air Mattress Pump System Model TS 105 UM 105 E V1 0 Copyright 2010 by TRUE SOURCE Technology Co Ltd...

Page 2: ...4 4 Product Setup Contents 5 5 Product Features 5 6 Installation 6 7 Initial Inflate Method 6 8 Emergency CPR Deflate 7 9 Power Unit Settings Contents 7 10 Routine Maintenance and Cleaning 8 11 Stora...

Page 3: ...the absolute responsibility and obligation to guarantee its full effects Power Unit Do not open the power unit without guidance to prevent danger Do not insert items into any opening of the power uni...

Page 4: ...flicted with spinal cord injury bedridden for a long term not clearly conscious inflicted with bladder or bowel incontinence diabetes skin fragility physical weakness or malnutrition It is an extremel...

Page 5: ...streamlined system appearance and practicality 4 The cotton air filter is to be replaced outside Therefore the replacement can be done without opening the unit 5 The use of the double external fuse ho...

Page 6: ...e the air mattress evenly on the overlay The end with a connector to the power unit is the feet end Step 2 Check if the securing position of the air cells is centered Secure the overlay of the bed wit...

Page 7: ...en the CPR lid When the patient lies down pull down hard on the plastic piece marked with CPR that drops from the chest position on the right side Then pull down the CPR lid for instant quick deflatio...

Page 8: ...ivers must wear gloves and masks and protected with disinfection 2 Keep the coverlet even to prevent the formation of horizontal shear resulted from crinkles and the tightened skin 3 Do not wash the a...

Page 9: ...s off 2 2 Repair or replacement is needed if the lid is damaged 2 3 Check if the mattress connector is bent or falls off 2 3 Repair or replacement is needed if the connector is deformed and cannot be...

Page 10: ...ass I Type BF The Air Mattress Specification Allow different setup for marketing Standard State 5 Air cells 21pcs totally Material Coverlet PU membrane Elastic Fabric Air Cells Nylon PU Base Nylon PVC...

Page 11: ...Only function failure repair is covered during the warranty period The warranty does not include general maintenance e g replacement of the cotton filter cleaning setting adjustment or component renew...