CHAPTER 7: ADDITIONAL INFORMATION
TRUEfitness.com / 800.426.6570 / 636.272.7100
43
TROUBLESHOOTING GUIDE (continued):
Malfunction
Possible Cause
Corrective Action
Heart rate is
displaying
erratically or not
displaying
Transmitter belt contacts are not
making good contact with the skin
Re-adjust the transmitter belt so that it is in full contact with
the skin
Contacts on the transmitter belt
are not moist
Moisten the contacts on the transmitter belt
Transmitter belt is not within 3 feet
(1 meter) of the heart rate receiver
Adjust your position on the belt so that you are within 3 feet (1
meter) of the console
The battery inside the transmitter
belt is depleted
replace the transmitter belt with a compatible transmitter belt
Another user wearing a compatible
transmitter strap is within 3 foot (1
meter) of the unit
Move the units so that there is more space in-between units
Heart rate is
displaying
erratically or not
displaying
(continued)
Environmental interference from
high voltage power lines
Move the unit to another position within the room or move
the cause of the interference until heart rate reading are stable.
If the probable source of interference is plugged into the same
outlet move the suspect source to another outlet.
Environmental interference from
computers
Environmental interference from
motor driven appliances
Environmental interference from
cell or cordless phone
Environmental interference from
Wi-Fi router
Fault Code
Category Description
Cause
Corrective Action
Fault CN00: Corrupted
Console Configuration Console
Corrupted brainboard
configuration - fails integrity
check
Corrupt software
Power cycle
Re-configure console
Firmware and
software versions are
not compatible
Re-install
software/firmware
Contact dealer or
TRUE service
Fault CN01: Internal
Fault
Console Math error - software
Console Configure
incorrectly
Power cycle
Re-configure console
Corrupt Software
Re-install
software/firmware
Contact dealer or
TRUE service
Fault CN02: Invalid
Console Configuration Console
The product configuration data
has failed validation checks
(incline ranges make no sense,
etc.)
Console Configure
incorrectly
Power cycle
Re-configure console
Incline Motor out of
range
Contact dealer or
TRUE service
Loose Cable