         Rev D, August 22, 2014 

9 of 11 

Manual number 9017682 

 

7.

 

Reduce the voltage of the power supply until Voltmeter reads 20.0V, then long press START 

on the 9015607 ONLY port.  The UUT should read CHARGING.  The ammeter should read 

220mA or greater.  The current displayed on screen should match the ammeter within 
±10mA.  Long press START on the 9015607 ONLY port.  The voltage displayed on screen 

should match the voltmeter within ±0.4V. 

 

8.

 

Increase the voltage of the power supply to 22.0V.  The UUT should display FLOAT.  

Voltmeter should read 22.0V ±0.4V, and ammeter should read -3mA ±1mA. 

 

9.

 

Move the test setup to the right side port labeled 9015607/9016925 with Battery Type switch 

selecting the 9015607 battery.  Adjust power supply to 22.0V. 

 

10.

 

Reduce the voltage of the power supply until Voltmeter reads 20.0V, then long press START 

on the 9015607/9016925 port.  The UUT should display CHARGING.  The ammeter should 

read 220mA or greater.  The current on screen should match the ammeter within ±10mA.  
Long press START on the 9015607/9016925 port.  The voltage displayed on UUT should 

match the voltmeter within ±0.4V. 

 

11.

 

Increase the voltage of the power supply to 22.0V.  The UUT should display FLOAT.  

Voltmeter should read 22.0V ±0.4V, and ammeter should read -3mA ±1mA. 

 

12.

 

Set Battery Type switch to the 9016925 position.  Reduce the voltage of the power supply 

until Voltmeter reads 20.0V.  Long press START on the 9015607/9016925 port.  The UUT 

should display CHARGING.  The ammeter should read 450mA or greater. 

 

13.

 

Long press START on the 9015607/9016925 port.  Increase the power supply to 22.0V.  The 

UUT should read FLOAT.  UUT voltage should display 22.0V ±0.4V and ammeter should read 
-3 mA ±1 mA. 

 

14.

 

Turn off power supply and the UUT. 

 

15.

 

Connect test setup per Figure 2: 

 

 

Figure 2:  Test Connections 

 

16.

 

Turn on the power supply and the UUT and adjust the voltage to 22.0V. 

 

AMMETER

VOLTMETER

POWER SUPPLY

TT43  BATTERY CHARGER & TESTER

+

+

+

+

+

Summary of Contents for TT43

Page 1: ...ter Charger True Blue Power is a division of Mid Continent Instrument Co Inc Mid Continent Instrument Co Inc dba Mid Continent Instruments and Avionics 9400 E 34th Street N Wichita KS 67226 Manual number 9017682 PH 800 821 1212 FX 316 630 0723 Rev D August 22 2014 ...

Page 2: ...t N Wichita KS 67226 USA Phone 316 630 0101 Fax 316 630 0723 www truebluepowerusa com www mcico com We welcome your comments concerning this manual Although every effort has been made to keep it free of errors some may occur When reporting a specific problem please describe it briefly and include the manual part number the paragraph figure table number and the page number Send your comments to Tru...

Page 3: ... Date Detail A 06 28 12 Initial release 5812 B 08 14 12 Clarification of wording in annual test procedure section Clarification of wording in section five paragraph one 6112 C 4 21 2014 Updated capacity test times for passing indication 6235 D 8 22 2014 Updated Section 3 Test Procedure for clarification ...

Page 4: ... of Contents SECTION 1 GENERAL DESCRIPTION 5 1 1 INTRODUCTION 5 1 2 FEATURES 5 SECTION 2 OPERATION 6 2 1 POWER 6 2 2 CHARGING BATTERY 6 2 3 TESTING BATTERY CAPACITY DISCHARGE TIME 7 SECTION 3 MAINTENANCE 8 3 1 TEST PROCEDURE FOR TT43 BATTERY TESTER CHARGER 8 3 2 RECYCLE INFORMATION 11 ...

Page 5: ...imarily with the 4300 4xx Electric Attitude Indicator and TS420 TS420 1 Battery Backup Systems 1 2 FEATURES Figure 1 Battery Charger Control Panel The following indicators are provided Digital Dot Matrix LCD Screen Displays current process i e charging testing Pass When illuminated indicates test of battery has tested good and battery does not need to be replaced Fail When illuminated indicates th...

Page 6: ... with the screen displaying CHARGING Full charge may take up to 6 hours depending on battery type The system will charge either two 9015607 batteries simultaneously or one 9015607 and one 9016925 simultaneously When full charge is reached the screen will indicate FLOAT When this is indicated the charger is now in float mode and will maintain the Battery in full charge condition IMPORTANT BATTERY I...

Page 7: ...n will become TEST DONE If discharge time is less than 60 minutes for 9015607 or less than 3 hours and 54 minutes for 9016925 the system will illuminate the FAIL indicator and it is recommended that the battery be replaced If discharge time is 60 minutes or more for 9015607 the PASS indicator will light and the system will continue discharging the battery If discharge time is 3 hours and 54 minute...

Page 8: ...rear connector of UUT 6430043 1 and into wall outlet Power on UUT The screen should display True Blue Power screen then change to the main battery screen 2 UUT should display 20 5V 0 2V for both ports 3 Long press START on the 9015607 ONLY port The red FAIL LED should turn on and the unit will alternate between a TEST DONE screen and the main battery screen Long press START again to clear Repeat t...

Page 9: ...7 9016925 port The UUT should display CHARGING The ammeter should read 220mA or greater The current on screen should match the ammeter within 10mA Long press START on the 9015607 9016925 port The voltage displayed on UUT should match the voltmeter within 0 4V 11 Increase the voltage of the power supply to 22 0V The UUT should display FLOAT Voltmeter should read 22 0V 0 4V and ammeter should read 3...

Page 10: ...tart counting up 22 The ammeter should read 246mA 10mA After approximately 5 to 10 seconds reduce the voltage of the power supply to less than 15 5V The UUT should display TEST DONE and illuminate the red FAIL LED 23 Long press START on the 9015607 9016925 port to clear the UUT back to the main battery screen The red FAIL LED should go out 24 Set the battery selection switch to 9016925 and adjust ...

Page 11: ...over and on an impervious surface B Keep spent batteries from freezing to avoid cracking their cases C DO NOT dispose of spent batteries in the trash or any landfill The battery contains lead and MUST be routed to a recycling center D Choose a reputable battery recycler Call 1 800 8BATTERY for a location near you or visit www rbrc org ...

Reviews: