17.
Long press START on the 9015607 ONLY port. The screen should change to TESTING, and
the timer should start counting up.
18.
The ammeter should read 246mA ±10mA. After approximately 5 to 10 seconds reduce the
voltage of the power supply to less than 15.5V. The UUT should display TEST DONE and
turn on the red FAIL LED.
19.
Long press START on the 9015607 ONLY port to clear the UUT back to the main battery
screen. The red FAIL LED should go out.
20.
Move the test setup to the right side port labeled 9015607/9016925 with Battery Type switch
selecting the 9015607 battery. Adjust power supply to 22.0V.
21.
Long press START on the 9015607/ 9016925 port. The screen should change to TESTING,
and the timer should start counting up.
22.
The ammeter should read 246mA ±10mA. After approximately 5 to 10 seconds reduce the
voltage of the power supply to less than 15.5V. The UUT should display TEST DONE and
illuminate the red FAIL LED.
23.
Long press START on the 9015607/9016925 port to clear the UUT back to the main battery
screen. The red FAIL LED should go out.
24.
Set the battery selection switch to 9016925 and adjust power supply to 22.0V.
25.
Long press START on the 9015607/9016925 port. The UUT should display TESTING and the
timer should count up. The fan should begin to run immediately.
26.
The ammeter should read 498mA ±10mA. After approximately 5 to 10 seconds reduce the
voltage of the power supply to less than 15.5V. The fan should stop running and the UUT
should display TEST DONE with the red “FAIL” LED on.
27.
Long press START on the 9015607/9016925 port to clear the UUT back to the main battery
screen. The red FAIL LED should go out.
28.