True Blue Power, Wichita, KS 

 

REV. B  February 11, 2014 

Manual Number 9018067 

 

INVERTER AC OUPUT

Pin B – AC Output 115VAC, 60Hz. Used for powering devices where terrestrial/utility power 

designations are used, pin B can be connected as “Line” or “Hot”.  
Pin C – AC Return 115VAC, 60Hz.  Used for powering devices where terrestrial/utility power 

designations are used, pin C can be connected as “Neutral”. 

Note:  Use of a circuit breaker on the AC output is optional. For the full 

output of 250VA, a 2.5 Amp circuit breaker is sufficient. For convenience at 

each AC outlet, individual circuit breakers of 1 to 3 amps each can be used. 

If a single pole breaker is used, install the breaker on the wire from pin B. If 
a double pole breaker is installed, route both pins B and C through the circuit 

breaker.

 

 

INVERTER REMOTE ON/OFF CONTROL: (see section 4.2.1) 
Pin E 
– Remote ON/OFF Control. Connecting this pin to either DC Negative or to aircraft 

ground will enable the AC output of the inverter. By utilizing a switch between this pin and 
ground or negative, it will allow remote on/off control of the unit. When unconnected (output 

is OFF) this pin will have approximately 16 VDC present, internally limited to less than 3 mA. 

If the inverter is to be enabled at all times, pin E can be connected to pin G.  
Pin G – Remote ON/OFF Return. This pin is internally connected to pin D. Pin G may be used  

as the return from an ON/OFF switch or left unconnected. It is recommended that pin G not  

be connected directly to ground or 28V negative. 
INVERTER FAULT INDICATION OUTPUT: 
Pin F – 
Fault Indication Output. This pin can be connected to an external LED or status  

monitoring device to indicated the operating status of the inverter. The inverter will provide  

Fault indication when: Power Output capability has been exceeded, the output has been  

short-circuited, the output is ground-faulted (GFI protection activated), or the inverter has  

shut-down in over-temperature protection. The output is an open-collector transistor with a  
weak pull-up to 28V (21K ohm) capable of sinking 100 mA. 
 
 

 

 

FIGURE 3.3 

TABLE 3.3 

  

 

PINOUT VIEW OF 

CONNECTOR PINOUT 

 UNIT 

CONNECTOR 

 

 

A

D

B

E

C

F

G

Pin #

A

24-32VDC  Input

B

115VAC  Output

C

Output  Return

D

Input Return

E

Remote On/Off

F

Fault Indication

G

Remote Return

Connector Pinout

Summary of Contents for TI250 Series

Page 1: ...es Static Electrical Power Inverter True Blue Power is a division of Mid Continent Instrument Co Inc Mid Continent Instrument Co Inc dba Mid Continent Instruments and Avionics 9400 E 34th Street N Manual Number 9018067 Wichita KS 67226 Rev B February 11 2014 ...

Page 2: ...hita KS 67226 USA Phone 316 630 0101 Fax 316 630 0723 www truebluepowerusa com www mcico com We welcome your comments concerning this manual Although every effort has been made to keep it free of errors some may occur When reporting a specific problem please describe it briefly and include the manual part number the paragraph figure table number and the page number Send your comments to True Blue ...

Page 3: ...True Blue Power Wichita KS REV B February 11 2014 3 Manual Number 9018067 REVISION DETAIL Rev Date Approved Detail A 12 10 13 BAW Initial release B 2 11 14 BMC Revised Technical Specifications ...

Page 4: ...RAL INFORMATION 3 2 UNPACKING AND INSPECTING 3 3 CABLE HARNESS 3 3 1 WIRE GAUGE SELECTION 3 3 2 PIN ASSIGNMENT INFORMATION 3 3 3 HARNESS VERIFICATION 3 4 MOUNTING 3 5 INSTALLATION COMPLETION SECTION 4 OPERATION 4 1 ELECTRICAL PERFORMANCE 4 2 PROTECTIVE FEATURES SECTION 5 CONFORMANCE 5 1 CONTINUED AIRWORTHINESS STATEMENT 5 2 ENVIRONMENTAL QUALIFICATION STATEMENT NUMBER LIST OF TABLES AND FIGURES 1 ...

Page 5: ...ugged extrusion that houses the unit is designed to help dissipate heat and provide mechanical strength against vibration or other possibilities of damage The TI250 is engineered to run cooler and features a fanless design which saves energy reduces weight and allows flexible installation locations At only 2 2 pounds it is lighter and smaller than competing inverters Additionally the primary stage...

Page 6: ...h as five inches past the unit connector to allow for back shell access to the connector 2 3 ROUTING OF CABLES The wires and cable bundle associated with the unit are heavy gauge wire and carry significant power Be aware of routing cables near other electronics or with other wire bundles that may be susceptible to high energy flow Avoid sharp bends in cabling and routing near aircraft control cabl...

Page 7: ...Pinout of Figure 3 3 Figure 3 4 and Wiring Diagram of Table 3 3 Refer to Section 2 Pre Installation Considerations in regards to routing precautions 3 3 1 WIRE GAUGE SELECTION Use of PTFE ETFE TFE Teflon or tefzel insulated wire is recommended for aircraft use Use the following wire gauges for each of the pins in the connector Pin A and C 14 AWG stranded or solid Pin B and D 18 AWG stranded or sol...

Page 8: ...it will allow remote on off control of the unit When unconnected output is OFF this pin will have approximately 16 VDC present internally limited to less than 3 mA If the inverter is to be enabled at all times pin E can be connected to pin G Pin G Remote ON OFF Return This pin is internally connected to pin D Pin G may be used as the return from an ON OFF switch or left unconnected It is recommend...

Page 9: ...True Blue Power Wichita KS REV B February 11 2014 9 Manual Number 9018067 FIGURE 3 4A Typical Small Aircraft Minimum Wiring Installation FIGURE 3 4B Typical Aircraft Wiring Installation ...

Page 10: ...True Blue Power Wichita KS REV B February 11 2014 10 Manual Number 9018067 FIGURE 3 4C Typical Aircraft Fixed Application Installation FIGURE 3 4D Fully Integrated Multi Inverter Aircraft Cabin System ...

Page 11: ...ad phillips screws or equivalent A lock washer under the head of each screw is recommended 3 5 INSTALLATION COMPLETION Prior to operating the unit in the aircraft it is recommended to verify the output and functionality of the unit In order to prevent accidental damage to other systems it is best not to attach the output to other equipment or power busses prior to verification Verify the output of...

Page 12: ...True Blue Power Wichita KS REV B February 11 2014 12 Manual Number 9018067 Connector per MS3102A 18 9P 2 0 4 75 5 0 5 50 5 94 4X Ø Ø 22 10 32 Mounting Holes 6 0 0 7 FIGURE 3 5 TI250 OUTLINE DRAWING ...

Page 13: ...trol of the inverter is also used to reset the inverter should an over current or GFI fault condition occur 4 2 2 OVER VOLTAGE When the input voltage exceeds the operating range of the unit See Section 1 2 1 absolute maximum input of 36VDC the unit senses an over voltage condition and disables the output The unit will dynamically monitor the input voltage such that if the input returns to within t...

Page 14: ... AC output will be disabled and the fault output will indicate Remove all inverter loads before re enabling the inverter 4 2 7 FAULT SHUTDOWN and INDICATION The TI250 monitors the AC output load its internal temperature and operation status Should the load be excessive or the inverter become too hot the inverter will disable the AC output and indicate a fault status on the fault output If the inve...

Page 15: ...ght Loss of Cooling Decompression Overpressure 4 4 5 1 4 5 2 4 5 5 4 6 2 4 6 3 Category F3 Y Operating Low Temp 55C Operating High Temp 70C Category Y 300 minutes 40C 75 Altitude 55 000 ft 15 000 ft Temperature Variation 5 Category S2 Humidity 6 Category B Operational Shock and Crash Safety 7 Category B Vibration 8 Category R Curve C C1 RCC1 Category U Curve G Explosion 9 Category X Waterproofness...

Reviews: