8
Menu name
Options
Description
Complies with ISO 24631-6 e.g. 1000000964000000123456. ISO
A 23 digit representation of the ISO format that uses a leading
A for animal tags and an R for non animal tags. e.g.
A0000000964000000123456 for an animal tag
R0000000964000000123456 for a non animal tag
ISO23
3. DUPLICATES
Select to ensure the panel reader
will not
record the same EID
twice in the same session.
ON**
Select to ensure the panel reader
will
record the same EID twice
in the same session.
OFF
4. READ MODE
Select to allow scanning of FDX and HDX tag types.
DUAL**
Select to allow scanning only of FDX tag types.
FDX
Select to allow scanning only of HDX tag types.
HDX
5. TX POWER
Select to maximise the read range of the panel reader to animal
tags.
HIGH**
Select to reduce the read range of the panel reader to animal
tags.
LOW
4. DIAGNOSTICS
There are four diagnostics screens which provide troubleshooting information.
Select NEXT to scroll through the screens. If the values fall outside the normal
range, see
Section - Troubleshooting.
Supply voltage
The power supply voltage is displayed and should be followed by (OK).
Antenna voltage
and tuning value
The antenna voltage is displayed and should be followed by (OK). The tuning
value is displayed. The graph should show a dot in the middle band and be
followed by (OK).
Noise level
Displays the levels of interference being detected. The noise level should be in the
lower part of the graph.
Read rate
Displays the reads per minute for the current location of the tag.
Default settings marked **