background image

Tru-Test Limited, New Zealand 

www.tru-test.com

 An ISO 9001 Quality Registered Company

FCC Notice

This Tru-Test model EziWeigh has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These 
limits are designed to provide reasonable protection against harmful interference when the equipment is used in a commercial environment. This equipment 
generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to 
radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case users will be required to correct 
the interference at their own expense.

INTERNAl 
BATTERY 
oPTIoN

SPECIFICATIoNS

The internal battery charger operates from either the recommended Tru-Test power adaptor or a 12 volt 
vehicle battery.  Damage to the indicator caused by other charging supplies, including automotive 
battery chargers, is not covered by the warranty.

The indicator displays 

 about 10 minutes before flat, if the battery was fully charged within 

the last 2 weeks. Charge the indicator for 12 hours before using it for the first time.

To maximise battery life, observe the following simple guidelines:
•  Preferably recharge the battery overnight.
•  Never charge the indicator in direct sunlight.
•  Store the indicator in a cool dry place.

The internal battery charger ensures maximum life of the battery, while giving the fastest charging 
rate possible. The battery is protected from overcharging. Charging a flat battery takes 6 hours at 
temperatures of 10 to 35 ºC (50 to 95 ºF).

You can safely leave the indicator on charge all the time. The scale can be used while charging. You do 
not need to charge before storage.

Charging at low or high temperatures could extend the charging time to 12 hours. At extreme 
temperatures the indicator will not charge. 

Fully charge the indicator after storage.

Cleaning:

Clean only with warm water and soap, other cleaners may damage the case.

Note: product specifications may change without prior notice.

Total Capacity 

2000 or 3000 kg (4400 or 6600 lb) depending on load bars used.

Resolution 

Set to 0.5 kg (fine mode 0.1 kg) or 1 lb (fine mode 0.2 lb).

Accuracy 

±1 % or 2 resolutions (whichever is greater) with Tru-Test load bars  

 

 

connected.

Power supply 

12 V DC (power adaptor or vehicle battery).

Operating temperature 

-10 to +40 ºC  (+14 to +104 ºF).

Storage temperature 

-20 to +35 ºC  (-4 to +95 ºF).

Internal battery run time 

8 hours with 2 load bars connected.

Environmental 

IP67 (immersion in 1 m of water).

Service Information:

For repair or service information, contact the supplier of your EziWeigh or visit our website at  
www.tru-test.com.

For online registration of warranties go to www.tru-test.com.

p

4