Troubleshooting 

General system faults 

If you encounter a problem with your electric fence security system, first ask your service agent for 
advice. 
If the unit detects a fault in the system, it will log a fault code, and the Power lamp will start 
flashing fast.  Additionally the beeper will sound in the Keyswitch and Keypad.  Ask your service 

agent for assistance. 
If the supply cord is damaged it must only be replaced by your service agent, in order to avoid a 
hazard. 

Keypad or Keyswitch faults 

In rare instances, the Keypad or Keyswitch may stop functioning normally (maybe after a bad 
lightning storm). In this instance, the Keypad or Keyswitch needs to be reset.  Ask your service 

agent for assistance. 

Summary of Contents for Electric Fence Security System

Page 1: ...e trademarks of Tru Test Corporation Limited No part of this publication may be photocopied reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical pho...

Page 2: ...t distinguishes sudden fence voltage changes from slow changes caused by environmental degradation Provision for up to four Keypads and or Keyswitches altogether Full gate access control using low vol...

Page 3: ...ator lamps these allow the unit to be installed on its own without a Keypad or Keyswitch It has the same full range of features and customisable settings as provided on the Premium but these are set b...

Page 4: ...factory default OPIN is 5555 The Keypad will give a short beep to confirm each key press a long high pitched beep after each successful command sequence and a long low pitched beep after an invalid c...

Page 5: ...right until a fast beeping is heard 3 Return the key back to the upright position and remove Disarming using the Keypad To disarm the system enter the UPIN or OPIN then press COMMAND KEY 1 KEY 2 KEY...

Page 6: ...tering Monitor mode using the Keypad To set Monitor mode enter the UPIN or OPIN then press COMMAND KEY 1 KEY 2 KEY 3 KEY 4 KEY 5 Monitor using User PIN U P I N or Owner PIN O P I N Note that in Monito...

Page 7: ...KEY 2 KEY 3 KEY 4 KEY 5 Return to Standby using User PIN U P I N or Owner PIN O P I N The system will disarm the Armed lamp will turn off and the Pulse lamp will stop flashing Tip You may instantly ac...

Page 8: ...Each subsequent activation of the alarm will normally cause the siren to be re triggered The siren can be silenced immediately by the user without deactivating the electric fence security system This...

Page 9: ...to your assistance The siren will not time out and will continue until you exit Panic mode Note A panic alarm cannot be raised using the Keyswitch Exiting Panic mode Exiting Panic mode using the Keys...

Page 10: ...ce of your installer On Mains power on and battery good Off Normal operation if armed system is secure Flashing Fence alarm condition present On Fence currently secure but the fence alarm has previous...

Page 11: ...ch where fitted If the gate has been left open after a short period has elapsed half of the exit delay time the chime will sound once every 10 seconds as a warning Tamper alarm If someone tampers with...

Page 12: ...uired to change these PIN numbers whereas the UPIN cannot do this even for the UPIN itself Setting the UPIN To set the UPIN enter the current OPIN followed by the command and then key in the new UPIN...

Page 13: ...lashing fast Additionally the beeper will sound in the Keyswitch and Keypad Ask your service agent for assistance If the supply cord is damaged it must only be replaced by your service agent in order...

Page 14: ...have it checked and repaired promptly by your service agent to ensure system integrity The Power Pack supply cord cannot be replaced If the cord is damaged the whole Power Pack should be replaced Ens...

Page 15: ...d their ancillary equipment shall be installed operated and maintained in a manner that minimizes danger to persons and reduces the risk of persons receiving an electric shock unless they attempt to p...

Page 16: ...ge not exceeding 1 000 V 15 m for power lines operating at a nominal voltage exceeding 1 000 V A spacing of 2 5 m shall be maintained between uninsulated electric security fence conductors or uninsula...

Page 17: ...suitable for use outdoors and is of a type with a minimum degree of protection IPX4 Figure 1 Symbol for warning sign Warranty This product is warranted against faulty material and workmanship for a p...

Reviews: