gas detector BG20

Display

8

9

10

11

12

13

14

15

16

17

No.

Designation

8

MUTE indication

9

MAX

 indication

10

Time

 indication

11

REC

 indication

12

Memory space indication

13

MEM

 indication

14

Battery indication

15

Indication of the unit ppm

16

Measurement value indication

17

CO

 indication

Technical data

Parameter

Value

Model

BG20

Weight

180 g

Dimensions (length x
width x height)

160 x 56 x 40 mm

Measuring range

0 ppm to 1000 ppm

Accuracy

±10 ppm or ±5 %(depending on
which value is larger)

Measuring range
resolution

1 ppm

Sensor type

Stabilised electrochemical gas-
specific (CO)

Sensor life (typically)

5 years

Memory

For 10 measured values

Warm-up period

< 20 seconds

Power supply

1 x 9 V battery

Battery life

approx. 50 hours for an alkaline cell

Operating temperature 0 °C to 50 °C (32 °F to 122 °F)

Storage temperature

-30 °C to 60 °C (-22 °F to 140 °F)

Operating humidity

0 % RH to 99 % RH (non-condensing)

Scope of delivery

1 x Device 

BG20

1 x 9 V battery

1 x Bag / holster

1 x Quick guide

Transport and storage

Note

If you store or transport the device improperly, the
device may be damaged.
Note the information regarding transport and storage of
the device.

Transport

For transporting the device, use the bag included in the scope of
delivery in order to protect the device from external influences.

Storage

When the device is not being used, observe the following
storage conditions:

dry and protected from frost and heat

protected from dust and direct sunlight

with a cover to protect it from invasive dust if necessary

The storage temperature is the same as the range given in
the Technical data chapter.

Remove the battery from the device.

Summary of Contents for Westinghouse WLE625 Series

Page 1: ...TRT BA BG20 TC2014 32 002 EN BG20 EN OPERATING MANUAL GAS DETECTOR ...

Page 2: ...afety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision ...

Page 3: ...ng and learn to recognize them Immediately remove persons who have inhaled carbon monoxide to fresh air Immediately seek medical help Warning of electrical voltage There is a risk of a short circuit due to liquids penetrating the housing Do not immerse the device and the accessories in water Make sure that no water or other liquids can enter the housing Warning of electrical voltage Work on the el...

Page 4: ...Nausea within 20 minutes death within 1 hour 3200 ppm Headache dizziness and nausea within 5 to 10 minutes Death within 25 to 30 minutes 12800 ppm Death within 1 to 3 minutes according to OSHA Occupational Safety Health Association Information about the device Device description The carbon monoxide measuring device BG20 serves the purpose of measuring the concentration ppm of carbon monoxide CO in...

Page 5: ...pprox 50 hours for an alkaline cell Operating temperature 0 C to 50 C 32 F to 122 F Storage temperature 30 C to 60 C 22 F to 140 F Operating humidity 0 RH to 99 RH non condensing Scope of delivery 1 x Device BG20 1 x 9 V battery 1 x Bag holster 1 x Quick guide Transport and storage Note If you store or transport the device improperly the device may be damaged Note the information regarding transpo...

Page 6: ...the label in the intended position at the rear of the device Switch on Note The device calibrates after each switch on taking the CO concentration in the environment as basis For reasons of safety however regardless of the actual CO concentration in the environment upon switch on the device accepts no more than 10 ppm as upper limit Example Should the background concentration of CO amount to 30 pp...

Page 7: ...d when last calling up the measured value memory will appear in the memory space 12 display 2 Press the SEL button 3 to save the current measured value Info The measured value memory is deleted when you perform a zero point reset see Resetting the zero point Calling up the alarm threshold The value for the alarm threshold is stipulated can however be called up at any time 1 Press the mode button 6...

Page 8: ...e device can no longer be switched on The battery is dead Insert a new battery see chapter Operation Display segments are only faintly visible or flicker The battery voltage is too low Disposal The icon with the crossed out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household waste at the end of its life You will find colle...

Page 9: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: