EN

6

conveying fan TTV 1500 / TTV 3000

Errors and faults

The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.

Note

Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.

The fan operates only for a brief period, then switches off:

Check whether the protective grid at the air inlet is
obstructed in some way. If applicable, remove foreign
objects.

The motor bearing might be damaged. Please contact the
customer service.

The fan is not running:

Check whether the device is switched on.

Check the power connection.

Check the power cable and mains plug for damages.

Check the on-site fusing.

Your device still does not operate correctly after these
checks?

Please contact the customer service. If necessary, bring the
device to an authorized specialist electrical company or to
Trotec for repair.

Maintenance

Activities required before starting maintenance

Warning of electrical voltage

Do not touch the mains plug with wet or damp hands.

Switch the device off.

Hold onto the mains plug while pulling the power cable out
of the mains socket.

Cleaning the housing

Clean the housing with a soft, damp and lint-free cloth. Make
sure that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth.

Cleaning the fan and device interior

Check fan and protective grid for perfect condition before
and after each application.

Clean the fan after each operation.

Use compressed air to remove particles, lint, dust and dirt
from motor, fan wheel and protective grid. Do not in any
event use a high-pressure cleaner to clean the fan.

Other than that, the device does not require maintenance.

Summary of Contents for TTV 1500

Page 1: ...TRT BA TTV1500 TTV3000 TC 003 EN TTV 1500 TTV 3000 EN OPERATING MANUAL CONVEYING FAN ...

Page 2: ... via the following link TTV 1500 https hub trotec com id 39417 TTV 3000 https hub trotec com id 39418 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or se...

Page 3: ...overheating protection which is activated by overheating of the device when exceeding the operating temperature In such an event the device switches off automatically Intended use The conveying fan TTV 1500 TTV 3000 may be used for aeration deaeration air circulation dust collection or air transport whilst adhering to the technical data and the safety instructions The device is designed for aerati...

Page 4: ... from humidity regulation to the transport of fresh air or exhaust air over longer distances The device is equipped with bilateral hose connectors allowing to connect for instance an air transport hose to the air inlet and a dust bag to the air outlet This makes the conveying fan an ideal transport fan for far off connected air conditioning or heating applications It thus allows to increase the co...

Page 5: ... one another Info Do not take the devices into operation when stacked Stacking rules out an efficient usage of the devices Assembly and start up Scope of delivery 1 x Device 1 x Manual Unpacking the device 1 Open the cardboard box and take the device out 2 Completely remove the packaging 3 Fully unwind the power cable Make sure that the power cable is not damaged and that you do not damage it duri...

Page 6: ...device off by setting the on off switch to position O 2 Hold onto the mains plug while pulling the power cable out of the socket 3 Clean the device according to the Maintenance chapter 4 Store the device according to the Storage chapter Available accessories Warning Only use accessories and additional equipment specified in the operating manual Using insertion tools or accessories other than those...

Page 7: ... service If necessary bring the device to an authorized specialist electrical company or to Trotec for repair Maintenance Activities required before starting maintenance Warning of electrical voltage Do not touch the mains plug with wet or damp hands Switch the device off Hold onto the mains plug while pulling the power cable out of the mains socket Cleaning the housing Clean the housing with a so...

Page 8: ... 0 m 0 5 m 0 5 m Weight 8 kg 17 kg Disposal The icon with the crossed out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household waste at the end of its life You will find collection points for free return of waste electrical and electronic equipment in your vicinity The addresses can be obtained from your municipality or loc...

Page 9: ......

Page 10: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: