background image

 

2

EN

User instructions – Adsorption dehumidifier TTR 160/250

Description of symbols

WARNING SYMBOL. This symbol is followed by haz-
ard warning instructions whose non-compliance 
may cause serious injuries and/or death and/or 
property damage. 

The note is always preceded by a signal word: 

Risk:

 

 Risk of serious or fatal injury

Warning:

 

Risk of serious permanent injury

Caution:

 

Risk of damage to property

Additional information which might be helpful when 
using the device. 

Typographical conventions

All text references to figures refer to the figures in the respective chapter. 
Position numbers that are not available in the respective chapter may 
refer to figures in the chapter "Description of device".

2.  Scope of delivery 

The scope of delivery of the device includes: 

• 

Dehumidifier

• 

Connection cable

• 

Operating manual

Further optional accessory parts can be ordered from the Trotec customer 
service.

3.  Warranty

The warranty period granted for the dehumidifier is 12 months or as oth-
erwise stated in the contract of purchase.  

Any damage to the device resulting from non-compliance with the in-
structions contained in this manual shall be excluded from the warranty.    

The manufacturer shall assume no liability for damages to the device 
and/or its accessories that are caused by unauthorised modifications.

For any further terms of guarantee, please refer to the General Terms and 
Conditions (GTC) available on our website: www.trotec.de.

1.  Notes on how to use the manual

Translation of the original instructions (2006/42/EC):

This operating manual contains all important information required for 
safe commissioning and use of the device.

It provides you with support for operating the device and remedying pos-
sible problems as well as with information on disposal and customer 
service.

Please read this manual thoroughly and completely before using the de-
vice for the first time. 

Please store this operating manual and keep it within reach in order to 
consult it if necessary. 

Please observe all safety instructions and information on use and main-
tenance contained in this manual. 

This manual should be attached to the device if the latter is made avail-
able to other persons for use.

Table of contents

1.  Notes on how to use the manual.................................................2

Description of symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Typographical conventions . . . . . . . . . . . . . . . . . . . . . . . . . . 2

2.  Scope of delivery  .......................................................................2
3. Warranty ....................................................................................2
4.  General safety instructions .........................................................3
5.  Proper use ..................................................................................3
6.  General information ....................................................................3

Functional principle  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

7.  Description of device ..................................................................5

Structure and components . . . . . . . . . . . . . . . . . . . . . . . . . . 5

8.  Set-up and commissioning .........................................................5

Set-up  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Presettings   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

9. Operation ...................................................................................6

Switching the device on . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Switching the device off . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Remote operation   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

10.  Transport and storage .................................................................6

Transport  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Storage  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

11.  Care and maintenance ................................................................6

Care . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Maintenance  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Replacing the filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

12.  Dangerous substances ...............................................................7
13. Disposal .....................................................................................8

Dehumidifier  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Packaging  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

14.  Service and repair ......................................................................8
15. Troubleshooting ..........................................................................9
16.  Technical data, Spare Parts.........................................................9

Summary of Contents for TTR 160

Page 1: ...User instructions Adsorption DehumidiFier TTR 160 TTR 250 EN EN...

Page 2: ...efer to the General Terms and Conditions GTC available on our website www trotec de 1 Notes on how to use the manual Translation of the original instructions 2006 42 EC This operating manual contains...

Page 3: ...annot be achieved with condensation dehumidifiers for physi cal reasons Additionally adsorption dehumidifiers are considerably more economic at these operating temperatures 4 General safety instructio...

Page 4: ...via the sections so that it can permanently absorb and release humidity Process air Air to be dehumidified is taken in by means of a fan and divided into two air streams Process air 4 and regeneration...

Page 5: ...ed To prevent an air short circuit with the humid exhaust air the humid air outlet of free intake devices is to be laid away at a minimum distance of approx 1 0 m from the device Presettings Ventilati...

Page 6: ...ill light up Switching the device off The device can be switched off at the power switch 6 The integrated control indicator will go out Remote operation The device can be switched on at the power swit...

Page 7: ...deteriorat ing effect on the dehumidification rotors silica gel used in this device Even small quantities of these or similar substances must be prevented from coming into contact with the device Inor...

Page 8: ...be disposed of in the designated containers according to local regulations or at a recycling depot 14 Service and repair Danger Danger to life due to improper repair Never attempt to carry out modifi...

Page 9: ...110 000 130 EAN number 4 052 138 000 784 4 052 138 002 445 Dehumidification performance 0 5 kg h 1 1 kg h Range of application for drying air 60 160 m h 130 300 m h Nominal air volume pressing 155 m...

Page 10: ...XS1 1 2 3 PE PE sw schwarz black rt rot red ge gelb yellow bl blau blue br braun brown K1 A1 A2 air dehumidifier TTR 160 no rev Titel E EA 160 0001 01 Trotec GmbH Grebbenerstr 7 52525 Heinsberg trans...

Page 11: ...XS1 1 2 3 PE PE sw schwarz black rt rot red ge gelb yellow bl blau blue br braun brown K1 A1 A2 air dehumidifier TTR 250 no rev Titel E EA 250 0002 01 Trotec GmbH Grebbenerstr 7 52525 Heinsberg trans...

Page 12: ...Dimensions TTR 160 40 199 50 60 DN63 98 DN100 38 306 306 82 213 28 244 40 50 61 24 304 40 Dimensions TTR 250 282 79 DN80 98 DN100 339 115 75 241 354 273 212 78 24...

Page 13: ...ective cover P 1000 1053 12 Ampere meter P 1000 1058 13 Operating hour counter P 1000 1137 14 Cable bushing P 1000 0973 15 Filter mat P 1000 1192 Item Designation Article number 16 Gear motor P 1000 1...

Page 14: ...ective cover P 1000 1053 12 Ampere meter P 1000 0179 13 Operating hour counter P 1000 1137 14 Cable bushing P 1000 0937 Item Designation Article number 15 Filter mat P 1000 1194 16 Gear motor P 1000 1...

Page 15: ...exigences fondamentales de s curit et de sant Cette d claration n est valable que dans la version que nous avons mise en circulation Funktion Adsorptions Luftentfeuchter Function Adsorption Air Dehum...

Page 16: ...trotec GmbH Grebbener str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...