3. Guide the hose through the hole in the device's side panel.
4. Refit the condensation tank into the device. Guide the other
hose end to a suitable drain or sufficiently dimensioned
collection container.
5. Please note that the hose must not be kinked.
Remove the hose if you want to collect the condensate in the
condensation tank again. Allow the hose to dry prior to storage.
Automatic defrost
At low ambient temperatures, ice may form at the evaporator
during dehumidification. The device will then carry out an
automatic defrost. Dehumidification is briefly interrupted during
defrosting. The fan keeps running.
The device comes with a hot gas automatic defrost system
based on the bypass procedure. Here, the hot gas of the
refrigerant circuit is used actively for fast and effective
defrosting. As soon as ice starts to form, a special valves opens
automatically, redirects the hot gas to the evaporator, and
closes again after defrosting is completed so that drying
operation can be continued via the regular refrigerant circuit.
Unlike air circulation defrosting, hot gas automatic defrosting
allows for considerably shorter defrost phases, which is an
essential requirement for effective dehumidification in low-
temperature surroundings (below 15 °C) such as unheated
rooms. After all, the actual dehumidification process only takes
place when defrosting is not in progress.
The duration of the defrost process can vary. Do
not
switch off
the device during automatic defrost. Do
not
remove the mains
plug from the mains socket.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
•
Switch off the device.
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
•
If necessary, remove the condensation drain hose and any
residual fluid from it.
•
Empty the condensation tank, if need be.
•
Clean the device according to the Maintenance chapter.
•
Store the device according to the Transport and storage
chapter.