Trotec TTK 75 ECO Original Instructions Manual Download Page 3

EN

3

dehumidifier TTK 75 ECO

Ensure that all electric cables outside of the device are
protected from damage (e.g. caused by animals). Never
use the device if electric cables or the power connection
are damaged!

The mains connection must correspond to the
specifications in the Technical annex.

Insert the mains plug into a properly fused mains socket.

Observe the device's power input, cable length and
intended use when selecting extensions to the power
cable. Completely unroll extension cables. Avoid electrical
overload.

Before carrying out maintenance, care or repair work on
the device, remove the mains plug from the mains socket.
Hold onto the mains plug while doing so.

Switch the device off and disconnect the power cable from
the mains socket when the device is not in use.

Do not under any circumstances use the device if you
detect damages on the mains plug or power cable. 
If the power cable is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Defective power cables pose a serious health risk!

When positioning the device, observe the minimum
distances from walls and other objects as well as the
storage and operating conditions specified in the Technical
annex.

Make sure that the air inlet and outlet are not obstructed.

Make sure that the suction side is kept free of dirt and
loose objects.

Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.

Only transport the device in an upright position with an
emptied condensation tank or drain hose.

Discharge the collected condensate before transport and
storage. Do not drink it. Health hazard!

Safety warnings for devices containing flammable
refrigerants

Only position the device in rooms where potentially leaking
refrigerant cannot accumulate.

Only position the device in rooms where there is no source
of ignition (e.g. open flames, an active gas appliance or an
electric heater).

Please note that the refrigerant is odourless.

Only install the device in compliance with the national
installation regulations.

Please observe the local regulations.

Observe the national gas regulations.

Only install, operate and store the device 

TTK 75 ECO

 in a

room measuring more than 4 m

2

.

Store the device in a way that no mechanical damage can
occur.

Please note that the connected pipelines must not contain
any sources of ignition.

R290 is a refrigerant that complies with European
environmental regulations. No part of the cooling circuit
may be perforated.

Observe the maximum refrigerant capacity in the technical
data.

Do not drill through or burn.

Do not use any means other than those recommended by
the manufacturer for accelerating the defrosting process.

Every person working with or at the refrigerant circuit must
be able to provide a certificate of qualification issued by a
body accredited by the industry, demonstrating their
competence in the safe use of refrigerants based on a
procedure well-known in the industry.

Service work may only be carried out in accordance with
the manufacturer's specifications. If maintenance and
repair work require the support of additional persons, the
person trained in handling flammable refrigerants shall
continuously supervise the work carried out.

Unventilated rooms, in which the device is installed,
operated or stored, must be built in a way to ensure that
potentially leaking refrigerant cannot accumulate. This
serves to avoid fire or explosion hazards resulting from an
ignition of the refrigerant by an electric furnace, cooking
stove or another ignition source.

The entire refrigerant circuit is a maintenance-free,
hermetically sealed system and may only be maintained or
repaired by specialist companies for cooling and air-
conditioning or by Trotec.

Intended use

Only use the device for drying and dehumidifying room air, while
adhering to and following the technical data.
Intended use comprises:

dehumidifying and drying:

– living rooms, bedrooms and basements
– holiday homes, camper vans

maintaining the dryness of:

– storage spaces, archives, laboratories, garages
– changing rooms etc.

Summary of Contents for TTK 75 ECO

Page 1: ...TRT BA TTK75ECO TC220105TTRT01 005 EN TTK 75 ECO EN ORIGINAL INSTRUCTIONS DEHUMIDIFIER...

Page 2: ...ting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and ins...

Page 3: ...ce or an electric heater Please note that the refrigerant is odourless Only install the device in compliance with the national installation regulations Please observe the local regulations Observe the...

Page 4: ...nufacturer s specifications and by persons having a certificate of qualification A corresponding repair manual is available from the manufacturer upon request Residual risks Danger Natural refrigerant...

Page 5: ...nto the condensation tank below It is fitted with a float to measure the filling level Once the maximum filling level of the condensation tank is reached or in case the condensation tank is not instal...

Page 6: ...sporting the device proceed as follows Set up the device in an upright position after transport Leave the device to rest for 12 to 24 hours so the refrigerant can accumulate within the compressor Wait...

Page 7: ...ectric heater Only put up the device in an upright stable position on firm ground Do not create tripping hazards when laying the power cable or other electric cables especially when positioning the de...

Page 8: ...r Assembly and start up you can switch it on Press the on off switch 2 The device starts to dehumidify in continuous operation Note Only use the device in an upright position otherwise the compressor...

Page 9: ...redirects the hot gas to the evaporator and closes again after defrosting is completed so that drying operation can be continued via the regular refrigerant circuit Unlike air circulation defrosting...

Page 10: ...operating range according to the technical data Ensure that the relative room humidity complies with the technical data Check the air filter for dirt If necessary clean or replace the air filter From...

Page 11: ...nd or drain hose X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign objects and...

Page 12: ...d labels on the device Check the safety signs and labels attached to the device at regular intervals Replace illegible safety signs Cleaning the housing Clean the housing with a soft damp and lint fre...

Page 13: ...lter into the device 4 Reinsert the air filter into the device Emptying the condensation tank If the condensation tank is full or not installed correctly the condensation tank indicator light 9 will b...

Page 14: ...chnical annex Technical data Parameter Value Model TTK 75 ECO Max dehumidification performance 21 l 24 h Dehumidification performance 30 C and 80 RH 20 l 24 h Air flow rate 260 m3 h Operating range te...

Page 15: ...LL red blue brown blue red white black brown blue blue VALVE FAN LAMP 3 4 N control chip N L fan comp R S C calculagraph water full lamp 2 way valve water full switch defrosting sensor blue blue brown...

Page 16: ...charge Tube 4 Three Exit Tube II 17 Discharge Tube II 30 Three Exit Tube 5 Three Exit Tube 18 Defrost Tube 31 Bypass Valve 6 Gas In Tube 19 Air Baffle 32 Right Faceplate 7 Filter 20 Fan Wheel 33 Compr...

Page 17: ...e national regulations by a company with the relevant certification European Waste Catalogue 160504 Declaration of conformity Declaration of conformity in accordance with the EC Machinery Directive 20...

Page 18: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: