Operating Manual – Dehumidifier TTK 75 E

EN

Cleaning the housing and condensation tank

1. Use a soft, lint-free cloth for cleaning.

2. Dampen the cloth with clean water. Do not use

sprays, solvents, alcohol-based or abrasive
cleaners to dampen the cloth.

A.

B.

C.

D.

Summary of Contents for TTK 75 E

Page 1: ...TTK 75 E OPERATING MANUAL DEHUMIDIFIER EN TRT BA TTK75E TC 002 EN...

Page 2: ......

Page 3: ...tronically pro cessing duplicating or spreading the publication Subject to technical changes All rights reserved Trademarks are used without guarantee that they may be used freely and primarily follow...

Page 4: ...ase into the condensation tray and through the integrated drain nozzle into the con densation tank 3 below This is fitted with a float to measure the fill level The device has a control panel 1 for op...

Page 5: ...idity 30 80 Volume of airflow max 192 m h Electric connection 230 V 50 Hz Power consumption max 355 W Fuse home 10 A Condensation tank 3 l Refrigerant R410a Amount of refrigerant 160 g Weight 12 3 kg...

Page 6: ...se the device TTK 75 E only for drying and dehumid ifying room air while adhering to and following the technical data Intended use encapsulates drying and dehumidifying living rooms bedrooms bathrooms...

Page 7: ...ight position where it is protected from dust and direct sunlight with a plastic cover to protect it from invasive dust if necessary The storage temperature is the same as the range given for the oper...

Page 8: ...automatic defrost is active 10 Condensation tank full indicator light Flashes once the maximum fill level of the condensation tank is reached or when the condensation tank is not installed correctly...

Page 9: ...right to CONTINUOUS Normal operation mode In normal operation mode the device stops the dehu midification once the desired room humidity has been reached When the humidity in the rooms increases the...

Page 10: ...pter Operating elements 2 Do not touch the mains plug with wet or damp hands 3 Remove the mains plug from the mains socket 4 Empty the condensation tank and wipe it dry with a clean cloth Check for dr...

Page 11: ...ta Check that the selected humidity is realistic The humidity in the room must be above the selected range Reduce the preselected relative humidity by turning the rotary switch 12 if necessary Check t...

Page 12: ...ace air filter X check for damages X check attachment screws X X carry out a test run X Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 check air inlets and outlets for dirt and f...

Page 13: ...ned must only be carried out by specialist companies for cooling and air conditioning or by TROTEC Visual check for dirt in the inside of the device 1 Remove the air filter see chapter Cleaning the ai...

Page 14: ...fier TTK 75 E EN Cleaning the housing and condensation tank 1 Use a soft lint free cloth for cleaning 2 Dampen the cloth with clean water Do not use sprays solvents alcohol based or abrasive cleaners...

Page 15: ...3 Cleaning the air inlets and the air filter Caution Ensure that the air filter is not worn or damaged Before reinserting the air filter ensure that it is dry Read the chapter Maintenance intervals an...

Page 16: ...oard 36 Fixture 7 Plate 22 Lamp assembly 37 Cover 8 Evaporator assembly 23 Knob 38 Cover 9 Condenser assembly 24 Capacitor 1 F 450 for fan motor 14 39 Humidity switch 10 Y tube 25 Fix metal 40 Sensor...

Page 17: ...ose of the refrigerant oil mixture appropri ately and according to the national regulations in accordance with the EC Low Voltage Directive 2006 95 EC Annex III Section B and the EC Directive 2004 108...

Page 18: ......

Page 19: ......

Page 20: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: