15
EN
Operating manual – dehumidifier TTK 30 E
4. Refit the condensation tank into the device.
Make sure not to damage the float when inserting or
removing the condensation tank.
In doing so, make sure that the float is positioned
correctly.
In doing so, make sure that the condensation tank is
inserted correctly, for otherwise the device cannot be
switched back on.
Activities required after maintenance
If you want to continue using the device:
•
Leave the device to rest for 12 to 24 hours, so the
refrigerant can accumulate within the compressor. Wait
12 to 24 hours before switching the device back on! Acting
contrary might lead to compressor damage and a
malfunctioning device. If so, any warranty claims will be
voided.
•
Reconnect the device to the mains.
If you do not intend to use the device for a considerable time:
•
Store the device according to the Storage chapter.
Technical annex
Technical data
Parameter
Value
Model
TTK 30 E
Dehumidifying capacity max.
12 l / 24 h
Air volume
120 m
3
/h
Operating range (temperature) 5 °C to 32 °C
Operating range (relative
humidity)
30 % to 80 % RH
Parameter
Value
Power supply
1/N/PE ~ 220-240 V / 50 Hz
Power consumption max.
0.27 kW
Nominal current
1.48 A
Refrigerant
R-134a
Amount of refrigerant
50 g
GWP factor
1.430
CO
2
equivalent
0.07 t
Water tank
2.2 l
Sound pressure level
45 dB(A)
Dimensions (length x width x
height)
220 x 280 x 415 mm
Minimum distance to walls and
other objects
A: top
B: rear
C: side
D: front
30 cm
30 cm
20 cm
20 cm
Weight
9 kg
Disposal
The icon with the crossed-out waste bin on waste
electrical or electronic equipment stipulates that this equipment
must not be disposed of with the household waste at the end of
its life. You will find collection points for free return of waste
electrical and electronic equipment in your vicinity. The
addresses can be obtained from your municipality or local
administration. For further return options provided by us please
refer to our website www.trotec24.com.
The separate collection of waste electrical and electronic
equipment aims to enable the re-use, recycling and other forms
of recovery of waste equipment as well as to prevent negative
effects for the environment and human health caused by the
disposal of hazardous substances potentially contained in the
equipment.
The device is operated with fluorinated greenhouse gas which
can be dangerous for the environment and contribute to global
warming when emitted to the atmosphere.
Further information is provided on the nameplate.
Dispose of the refrigerant appropriately and according to the
national regulations.