background image

8

EN

dehumidifier TTK 26 E

Operation

Notes:

Avoid open doors and windows.

After being switched on, the device operates fully
automatically.

The fan continues to run in dehumidification mode even
after the selected setpoint has been reached.

Operating elements

10

11 12 13

14 15

16 17

18

24

23

22

21

20

19

No. Designation

Meaning

10

Timer

 LED

Illuminated when the timer is
activated.

11

Inside drying

 LED Illuminated when the self-cleaning

function is activated

12

Low

 LED

Is illuminated at low fan speed

13

High

 LED

Is illuminated at high fan speed
(function for drying laundry)

14

Condensation
tank full

 LED

Is illuminated if the condensation tank
is full or not installed correctly

15 Segment display

Indicates the relative humidity level
and the number of hours of the timer

16

Continuous

 LED

Is illuminated if the continuous
operation mode is selected

17

Auto

 LED

Is illuminated if the automatic
operation mode is selected

18

Operation

 LED

Is illuminated when the device is
switched on.

19

On/off

 button

Switching the device on or off

20

Mode

 button

Changing the operating mode

21

Humidity

 button

For setting the desired relative
humidity level

22

Speed

 button

For setting the desired fan speed
(function for drying laundry)

23

Drying

 button

Switching the self-cleaning function on
or off

24

Timer

 button

For switching the timer function on
and off: 1 h to 24 h

Switching the device on

Once you have completely installed the device as described in
the Start-up chapter, you can switch it on.

1. Press the 

On / Off

 button (19).

ð

The 

operation

 LED (18) is illuminated.

Setting the operating mode

1. Repeatedly press the 

mode

 button (20) to change the

operating mode.

ð

In continuous operation mode, the 

continuous

 (16) LED

is illuminated.

ð

In automatic operation mode, the 

auto

 (17) LED is

illuminated.

Automatic operation

The device dehumidifies the air continuously until the set
relative humidity level is reached.
Please proceed as follows to adjust the desired humidity value:

1. Repeatedly press the 

humidity

 button (21).

ð

The selected humidity value is indicated on the segment
display (15).

This operating mode can also be used for drying laundry. To do
so, select the highest fan speed and observe the recommended
humidity values listed under 

laundry drying

.

Continuous operation

Regardless of the humidity level, the device dehumidifies
continuously.
In continuous operation, only the fan speed can be manually
selected.

Setting the fan speed

You can change between low and high fan speed.

1. Press the 

fan

 button (22).

ð

If the fan speed is set to a low level, the 

low

 LED (12) is

illuminated.

ð

If the fan speed is set to a high level, the 

high

 LED (13,

laundry drying function) is illuminated.

Auto stop function

If the condensation tank is full or not inserted correctly, the
device will stop automatically. 
The 

tank full

 LED (14) is illuminated.

Memory function

If you switch the device back on again, the settings selected for
the operating mode, the relative humidity level and fan speed
are saved.
The device memorises the settings even during short power
failures. In this case, the device automatically switches back on.
The previous settings are saved.

Summary of Contents for TTK 26 E

Page 1: ...TRT BA TTK26E TC2017 50 006 EN TTK 26 E EN OPERATING MANUAL DEHUMIDIFIER...

Page 2: ...otec com id 41301 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warni...

Page 3: ...en flames an active gas appliance or an electric heater Please note that the refrigerant is odourless Only install the device in compliance with the national installation regulations Observe the natio...

Page 4: ...ailable from the manufacturer upon request Residual risks Danger Natural refrigerant propane R290 H220 Extremely flammable gas H280 Contains gas under pressure may explode if heated P210 Keep away fro...

Page 5: ...panel for operating and controlling the functions Once the maximum filling level of the condensation tank is reached or in case the condensation tank is not installed correctly the condensation tank...

Page 6: ...ack on Acting contrary might lead to compressor damage and a malfunctioning device If so any warranty claims will be voided Storage Before storing the device proceed as follows Drain the remaining con...

Page 7: ...d When positioning the device keep a sufficient distance to heat sources Make sure that no curtains or other objects interfere with the air flow When positioning the device particularly in wet areas s...

Page 8: ...tart up chapter you can switch it on 1 Press the On Off button 19 The operation LED 18 is illuminated Setting the operating mode 1 Repeatedly press the mode button 20 to change the operating mode In c...

Page 9: ...ter a predefined number of hours 1 to max 24 hrs you can programme the timer The timer can be set in all operating modes You can activate the function when the device is switched off Automatic switch...

Page 10: ...paces When positioning the device or a clothes horse please observe the minimum distances specified in the technical data The following humidity values are suitable for drying laundry cupboard dry 46...

Page 11: ...side check the condenser for dirt see chapter Maintenance If the condenser is dirty have it cleaned by a specialist company or by Trotec The device might carry out an automatic defrost During automati...

Page 12: ...or drain hose X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign objects and cl...

Page 13: ...the device Check the safety signs and labels attached to the device at regular intervals Replace illegible safety signs Cleaning the housing Clean the housing with a soft damp and lint free cloth Ens...

Page 14: ...he device 6 Refit the condensation tank into the device Make sure not to damage the float when inserting or removing the condensation tank In doing so make sure that the float is positioned correctly...

Page 15: ...y might lead to compressor damage and a malfunctioning device If so any warranty claims will be voided Reconnect the device to the mains If you do not intend to use the device for a considerable time...

Page 16: ...16 EN dehumidifier TTK 26 E Wiring diagram...

Page 17: ...t No Spare Part 1 Water tank 11 Axle 21 Right buckle 2 Front Panel 12 PCB box 22 Anion Generator 3 Filter 13 PCB 23 Display 4 Float 14 Evaporator 24 Handle 5 Water Bracket 15 Back panel 25 Top cover 6...

Page 18: ...dministration For further return options provided by us please refer to our website https de trotec com shop The separate collection of waste electrical and electronic equipment aims to enable the re...

Page 19: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: