Errors and faults

The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.

The device does not start:

Check the power connection.

Check the power cable and mains plug for damage.

Check the on-site fusing.

Check the filling level of the condensation tank, and empty
it if necessary. The 

condensation tank full

 LED must not be

illuminated.

Check the condensation tank for correct seating.

Check the room temperature. Observe the device's
permissible operating range according to the technical
data. Possibly, the device does not start because the
ambient temperature is too low (< 5 °C).

Wait for 10 minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.

The device is running, but there is no formation of
condensate:

Check the float in the condensation tank for dirt. If
necessary, clean the condensation tank. The float must be
able to move freely.

Check the room temperature. Observe the device's
permissible operating range according to the technical
data. Possibly, the device does not start because the
ambient temperature is too low (< 5 °C).

Ensure that the relative room humidity complies with the
technical data.

Check the air filter for dirt. If necessary, clean or replace
the air filter.

From the outside, check the condenser for dirt (see
chapter Maintenance). If the condenser is dirty, have it
cleaned by a specialist company or by Trotec.

The device might carry out an automatic defrost. During
automatic defrost, the device does not dehumidify.

The device is loud or vibrates:

Check whether the device is set up in a stable and upright
position.

Condensate is leaking:

Check the device for leaks.

The compressor does not start:

Check the room temperature. Observe the device's
permissible operating range according to the technical
data. Possibly, the device does not start because the
ambient temperature is too low (< 5 °C).

Ensure that the relative room humidity complies with the
technical data.

Check whether the overheating protection of the
compressor has tripped. Disconnect the device from the
mains and let it cool down for approx. 10 minutes before
reconnecting it.

The device might carry out an automatic defrost. During
automatic defrost, the device does not dehumidify.

The device gets very warm, is loud or is losing
performance:

Check the air inlets and air filters for dirt. Remove external
dirt.

From the outside, check the device for dirt (see chapter
Maintenance). If the inside of the device is dirty, have it
cleaned by a specialist company for cooling and air-
conditioning or by Trotec.

Note

Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.

Your device still does not operate correctly after these
checks?

Please contact the customer service. If necessary, bring the
device to a specialist company for cooling and air-conditioning
or to Trotec for repair.

Summary of Contents for TTK 26 E

Page 1: ...TRT BA TTK26E TC2017 50 006 EN TTK 26 E EN OPERATING MANUAL DEHUMIDIFIER...

Page 2: ...otec com id 41301 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warni...

Page 3: ...en flames an active gas appliance or an electric heater Please note that the refrigerant is odourless Only install the device in compliance with the national installation regulations Observe the natio...

Page 4: ...ailable from the manufacturer upon request Residual risks Danger Natural refrigerant propane R290 H220 Extremely flammable gas H280 Contains gas under pressure may explode if heated P210 Keep away fro...

Page 5: ...panel for operating and controlling the functions Once the maximum filling level of the condensation tank is reached or in case the condensation tank is not installed correctly the condensation tank...

Page 6: ...ack on Acting contrary might lead to compressor damage and a malfunctioning device If so any warranty claims will be voided Storage Before storing the device proceed as follows Drain the remaining con...

Page 7: ...d When positioning the device keep a sufficient distance to heat sources Make sure that no curtains or other objects interfere with the air flow When positioning the device particularly in wet areas s...

Page 8: ...tart up chapter you can switch it on 1 Press the On Off button 19 The operation LED 18 is illuminated Setting the operating mode 1 Repeatedly press the mode button 20 to change the operating mode In c...

Page 9: ...ter a predefined number of hours 1 to max 24 hrs you can programme the timer The timer can be set in all operating modes You can activate the function when the device is switched off Automatic switch...

Page 10: ...paces When positioning the device or a clothes horse please observe the minimum distances specified in the technical data The following humidity values are suitable for drying laundry cupboard dry 46...

Page 11: ...side check the condenser for dirt see chapter Maintenance If the condenser is dirty have it cleaned by a specialist company or by Trotec The device might carry out an automatic defrost During automati...

Page 12: ...or drain hose X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign objects and cl...

Page 13: ...the device Check the safety signs and labels attached to the device at regular intervals Replace illegible safety signs Cleaning the housing Clean the housing with a soft damp and lint free cloth Ens...

Page 14: ...he device 6 Refit the condensation tank into the device Make sure not to damage the float when inserting or removing the condensation tank In doing so make sure that the float is positioned correctly...

Page 15: ...y might lead to compressor damage and a malfunctioning device If so any warranty claims will be voided Reconnect the device to the mains If you do not intend to use the device for a considerable time...

Page 16: ...16 EN dehumidifier TTK 26 E Wiring diagram...

Page 17: ...t No Spare Part 1 Water tank 11 Axle 21 Right buckle 2 Front Panel 12 PCB box 22 Anion Generator 3 Filter 13 PCB 23 Display 4 Float 14 Evaporator 24 Handle 5 Water Bracket 15 Back panel 25 Top cover 6...

Page 18: ...dministration For further return options provided by us please refer to our website https de trotec com shop The separate collection of waste electrical and electronic equipment aims to enable the re...

Page 19: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: