dehumidifier TTK 96 E / TTK 127 E
Overview of spare parts TTK 96 E
Note:
The position numbers of the spare parts differ from those
describing the positions of the components mentioned in theseinstructions.
Page 1: ...TRT BA TTK96E TTK127E TC2015 42 005 EN TTK 96 E TTK 127 E EN OPERATING MANUAL DEHUMIDIFIER...
Page 2: ...ity via the following link TTK 96 E https hub trotec com id 42501 TTK 127 E https hub trotec com id 42502 Safety Read this manual carefully before starting or using the device Always store the manual...
Page 3: ...sport and storage Do not drink it Health hazard Safety warnings for devices containing flammable refrigerants Only position the device in rooms where potentially leaking refrigerant cannot accumulate...
Page 4: ...misuse Personnel qualifications People who use this device must be aware of the dangers that occur when working with electric devices in damp areas have read and understood the operating manual espec...
Page 5: ...to the mains Information about the device Device description The device uses the principle of condensation to automatically dehumidify rooms The fan sucks damp room air through the air inlet the air...
Page 6: ...gether can be gathered from the applicable transport regulations To make the device easier to transport it is fitted with a carry handle To make the device easier to transport it is fitted with wheels...
Page 7: ...ther devices or objects on top of the device to prevent it from being damaged Assembly and start up Scope of delivery 1 x Device 1 x Air filter 1 x Power cable holder 1 x Hose adapter for condensation...
Page 8: ...h the air flow When positioning the device particularly in wet areas secure it locally with an RCD residual current device which complies with the respective regulations Inserting the air filter Note...
Page 9: ...level Indication of the relative room humidity level during set up Indication of the number of hours during timer programming Indication of error codes 21 POWER button Power button Switching the devi...
Page 10: ...ss the COMFORT button 27 to switch comfort mode on or off Setting the timer For the device to switch on or off automatically after a predefined number of hours max 24 hrs you can programme the timer T...
Page 11: ...densation connection For continuous operation or unattended dehumidification please connect the supplied condensation drain hose to the device The supplied hose is ready for use The supplied hose adap...
Page 12: ...he power connection Check the power cable and mains plug for damage Check the on site fusing Check the filling level of the condensation tank and empty it if necessary The Full LED 17 must not be illu...
Page 13: ...r cooling and air conditioning or by Trotec Note Wait for at least 3 minutes after maintenance and repair work Only then switch the device back on The device still does not operate correctly after the...
Page 14: ...ion tank and or drain hose X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign o...
Page 15: ...c Safety signs and labels on the device Check the safety signs and labels attached to the device at regular intervals Replace illegible safety signs Cleaning the housing Clean the housing with a soft...
Page 16: ...on 26 to carry out a filter reset This is only possible when the Filter LED 13 was previously illuminated After the reset the LED goes out Emptying the condensation tank If the condensation tank is fu...
Page 17: ...e switched back on Activities required after maintenance If you want to continue using the device Leave the device to rest for 12 to 24 hours so the refrigerant can accumulate within the compressor Wa...
Page 18: ...side 1 0 MPa 1 0 MPa Pressure outlet side 2 6 MPa 2 6 MPa Max permissible pressure 2 6 MPa 2 6 MPa Mains connection 1 N PE 220 240 V 50 Hz 1 N PE 220 240 V 50 Hz Max power consumption 0 72 kW 1 06 kW...
Page 19: ...EN 19 dehumidifier TTK 96 E TTK 127 E Circuit diagram TTK 96 E TTK 127 E...
Page 20: ...N dehumidifier TTK 96 E TTK 127 E Overview of spare parts TTK 96 E Note The position numbers of the spare parts differ from those describing the positions of the components mentioned in these instruct...
Page 21: ...3 4 Supporter Subassembly Of Fan Motor 1 17 Middle Partition Board Assembly 1 4 Capacitor Cap 1 17 1 Partition Board Subassembly 1 5 Capacitor Of Compressor 1 17 2 Micro Switch 1 6 Fixed Speed Rotary...
Page 22: ...dehumidifier TTK 96 E TTK 127 E Overview of spare parts TTK 127 E Note The position numbers of the spare parts differ from those describing the positions of the components mentioned in these instruct...
Page 23: ...Single Phase Asynchronous Motor 1 17 Middle Partition Board Assembly 1 3 4 Supporter Subassembly Of Fan Motor 1 17 1 Partition Board Subassembly 1 4 Capacitor Box 1 17 2 Micro Switch 1 5 Capacitor Of...
Page 24: ...y for many EU countries on the website https hub trotec com id 45090 Otherwise please contact an official recycling centre for electronic and electrical equipment authorised for your country The separ...
Page 25: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...