background image

EN

11

infrared heating panel TIH 350+ / TIH 650+

Errors and faults

Warning of electrical voltage
Tasks which require the housing to be opened
must only be carried out by authorised specialist
companies or by Trotec.

The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.

The device does not start:

Check the power connection.

Check the power cable and mains plug for damages.

Check the on-site fusing.

The surface of the device bulges outward:

The material expands due to heating. This is a perfectly
normal process. No measures are required.

The surface of the device only heats up slightly:

The mains voltage does not meet the requirements. Check
the mains voltage.

The ambient temperature is low. This is a perfectly normal
process. No measures are required.

The device makes noises after switch-on:

The material expands due to heating. The insulation
expands as well and might generate noises. This is a
perfectly normal process. No measures are required.

Note

Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.

Your device still does not operate correctly after these
checks?

Please contact the customer service. If necessary, bring the
device to an authorized specialist electrical company or to
Trotec for repair.

Maintenance

Activities required before starting maintenance

Warning of electrical voltage

Do not touch the mains plug with wet or damp hands.

Switch the device off.

Hold onto the mains plug while pulling the power cable out
of the mains socket.

Allow the device to cool down completely.

Warning of electrical voltage
Tasks which require the housing to be opened
must only be carried out by authorised specialist
companies or by Trotec.

Cleaning the device

Warning of electrical voltage

Never immerse the device in water!

Clean the device with a soft, damp and lint-free cloth. Ensure
that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth.
Wipe the housing dry after cleaning.

Summary of Contents for TIH 350+

Page 1: ...TRT BA TIH350 _TIH650 TC2018 53 001 EN TIH 350 TIH 650 EN OPERATING MANUAL INFRARED HEATING PANEL ...

Page 2: ...ormity via the following link TIH 350 https hub trotec com id 42748 TIH 650 https hub trotec com id 42749 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and o...

Page 3: ...ust be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Defective power cables pose a serious health risk During the installation of the device observe the minimum distances from walls and other objects as well as the storage and operating conditions specified in the Technical data chapter Never drill into the heating panel Do not use the dev...

Page 4: ...r improper way Observe the personnel qualifications Warning The device is not a toy and does not belong in the hands of children Warning Risk of suffocation Do not leave the packaging lying around Children may use it as a dangerous toy Warning Risk of injury due to infrared radiation Do not stay in the device s immediate vicinity for too long Do not look directly into the device for too long Obser...

Page 5: ...G The MessEG regulates the recording and transfer of measurement readings based on which the power consumption costs of the devices shall be determined Radiation The wavelength of the thermal radiation produced by the devices TIH 350 TIH 650 lies within the IR C range The wavelength depends on the respective surface temperature of the heating panel and thus on the ambient temperature in the room w...

Page 6: ... infrared heating panel TIH 350 TIH 650 Device depiction TIH 350 1 2 3 4 5 TIH 650 1 2 3 4 5 No Designation 1 foot 2 energy consumption meter 3 electric control box 4 power cable with plug 5 radiating side ...

Page 7: ...t and direct sunlight with a cover to protect it from invasive dust if necessary Place no further devices or objects on top of the device to prevent it from being damaged Assembly and installation Scope of delivery 1 x Device 1 x Manual 2 x Foot Unpacking the device 1 Open the cardboard box and take the device out 2 Completely remove the packaging 3 Fully unwind the power cable Make sure that the ...

Page 8: ...ories To do so please observe the information supplied with the stacking handles TIH 350 and TIH 650 can be combined in any desired stacking order Caution Risk of injury Ensure the secure footing and stable positioning of the stacked installation Provide additional safety measures if required Assembly for irradiating higher wall surfaces optional The devices can only be properly mounted for irradi...

Page 9: ...e installed both upright and horizontally Always set the infrared heating panel up in a way that the dark radiating side 5 faces a wall The distance to the wall may amount to maximally 20 cm Observe any regulations applicable for the installation site during the set up of the infrared heating panel Start up When positioning the device observe the minimum distance from walls or other objects as des...

Page 10: ...g while pulling the power cable out of the mains socket ð The energy consumption meter 2 goes out 2 Allow the device to cool down completely 3 Clean the device according to the Maintenance chapter 4 Store the device according to the Storage chapter Available accessories Warning Only use accessories and additional equipment specified in the operating manual Using insertion tools or accessories othe...

Page 11: ...s This is a perfectly normal process No measures are required Note Wait for at least 3 minutes after maintenance and repair work Only then switch the device back on Your device still does not operate correctly after these checks Please contact the customer service If necessary bring the device to an authorized specialist electrical company or to Trotec for repair Maintenance Activities required be...

Page 12: ...re 85 C 85 C Protection type IP 44 IP 44 Weight 6 5 kg 10 7 kg Dimensions width x height2 x depth2 1370 x 367 x 36 mm 1370 x 625 x 36 mm Minimum distance to walls and other objects A top B rear C side D front 6 cm 6 cm 6 cm 6 cm 6 cm 6 cm 6 cm 6 cm 1 The indicated temperature refers to temperature at the heating element 2 without feet Performance of the TIH 350 depending on the heating film temper...

Page 13: ...electronic equipment in your vicinity The addresses can be obtained from your municipality or local administration For further return options provided by us please refer to our website www trotec24 com The separate collection of waste electrical and electronic equipment aims to enable the re use recycling and other forms of recovery of waste equipment as well as to prevent negative effects for the...

Page 14: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: