electric heater TDX 10 / TDX 19

Shutdown

Warning of electrical voltage

Do not touch the mains plug with wet or damp hands.

TDX 10

Turn the rotary switch 

temperature

 (

2

) to position 

MIN

.

Switch off the device by setting the selector switch

ventilation and heating levels

 (

7

) to the 

0

 position.

Hold onto the mains plug while pulling the power cable out
of the mains socket.

Allow the device to cool down completely.

Clean the device according to the Maintenance chapter.

Store the device according to the Storage chapter.

TDX 19

Turn the rotary switch 

temperature

 (

2

) to position 

MIN

.

Turn the selection switch ventilation and heating levels (

7

)

to the ventilation position  .

Keep the fan running for 3 minutes before switching the
device off.

Switch off the device by setting the selector switch
ventilation and heating levels (

7

) to the 

0

 position.

Hold onto the mains plug while pulling the power cable out
of the mains socket.

Allow the device to cool down completely.

Clean the device according to the Maintenance chapter.

Store the device according to the Transport and storage
chapter.

Errors and faults

Warning of electrical voltage
Tasks which require the device to be opened must
only be carried out by authorised specialist
companies or by Trotec.

The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.

The device does not start:

Check the power connection.

Check the power cable and mains plug for damage. If you
notice damages, do not try to take the device back into
operation.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.

Check the on-site fusing.

The motor might be defective. Have a defective motor
replaced by a specialist electrical company.

The room thermostat might be defective. Have a defective
room thermostat replaced by a specialist electrical
company.

Wait for 10 minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.

The device is switched on, the fan is operating, the heating
is not:

Check the room temperature. The room thermostat may
have switched off, because the desired room temperature
has been reached.

Check whether the overheating protection has tripped (see
chapter Safety).

The heating resistor might have blown. Have a defective
heating resistor replaced by a specialist electrical
company.

The room thermostat might be defective. Have a defective
room thermostat replaced by a specialist electrical
company.

The fan is not running:

Check whether the device is switched on.

Check the power connection.

Check the power cable and mains plug for damages.

The fan motor might be defective. Have a defective fan
motor replaced by a specialist electrical company.

The air current is reduced:

Check the air inlet and outlet. Make sure that air inlet and
outlet are not obstructed. Remove any dirt. Observe the
minimum distance from walls or other objects according to
the technical data.

The device is loud or vibrates:

Check whether the device is set up in a stable and upright
position.

Note

Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.

The device still does not operate correctly after these
checks:

Please contact the customer service. If necessary, bring the
device to an authorised specialist electrical company or to
Trotec for repair.

Summary of Contents for TDX 10

Page 1: ...TRT BA TDX10 TDX19 TC220719TTRT01 003 EN TDX 10 TDX 19 EN ORIGINAL INSTRUCTIONS ELECTRIC HEATER ...

Page 2: ...ps hub trotec com id 45463 TDX 19 https hub trotec com id 45464 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and ins...

Page 3: ...e power cable is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Defective power cables pose a serious health risk When positioning the device observe the minimum distances from walls and other objects as well as the storage and operating conditions specified in the Technical annex Keep a safety distance of at least 1 m be...

Page 4: ... the device as intended Warning Dangers can occur at the device when it is used by untrained people in an unprofessional or improper way Observe the personnel qualifications Warning The device is not a toy and does not belong in the hands of children Warning Risk of suffocation Do not leave the packaging lying around Children may use it as a dangerous toy Warning Improper installation entails a ri...

Page 5: ...TDX 19 Device depiction TDX 10 1 2 7 3 4 6 5 6 TDX 19 1 2 3 4 6 7 6 5 No Designation 1 Transport handle 2 Rotary switch temperature 3 Air outlet 4 Foot 5 Air inlet 6 Setting wheel 7 Selection switch ventilation and heating levels ...

Page 6: ...and direct sunlight If required use a cover to protect the device from invasive dust Place no further devices or objects on top of the device to prevent it from being damaged Assembly and start up Scope of delivery 1 x Electric heater 1 x manual Unpacking the device 1 Open the cardboard box and take the device out 2 Completely remove the packaging 3 Fully unwind the power cable Make sure that the ...

Page 7: ...on switch ventilation and heating levels For selecting the heating levels and ventilation 0 OFF heating level 1 heating level 2 TDX 19 2 7 No Designation Meaning 2 Rotary switch temperature For setting the temperature via the room thermostat 7 Selection switch ventilation and heating levels For selecting the heating levels and ventilation 0 OFF cold air ventilation heating level 1 heating level 2 ...

Page 8: ...the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Check the on site fusing The motor might be defective Have a defective motor replaced by a specialist electrical company The room thermostat might be defective Have a defective room thermostat replaced by a specialist electrical company Wait for 10 minutes before restarting the device If the device is not ...

Page 9: ...ws X X Test run X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign objects and clean if necessary Check air inlet grid s for dirt and foreign objects and clean if necessary Clean the exterior Visually check the inside of the device for dirt Check for damage Check attachment scre...

Page 10: ...ve cleaning agents such as cleaning sprays solvents alcohol based or abrasive cleaners to dampen the cloth Wipe the housing dry after cleaning Technical annex Technical data Parameter Value Model TDX 10 TDX 19 Heating capacity level 1 level 2 level 3 1000 W 2000 W ventilation only 1500 W 3000 W Amount of air 100 l h 200 l h Operating range 10 C to 25 C 10 C to 25 C Mains connection 220 240 V 50 60...

Page 11: ...EN 11 electric heater TDX 10 TDX 19 Circuit diagram TDX 10 Circuit diagram TDX 19 ...

Page 12: ...ic heater TDX 10 TDX 19 Overview of spare parts and spare parts list TDX 10 Note The position numbers of the spare parts differ from those describing the positions of the components mentioned in these instructions ...

Page 13: ...5 Outer sheet cold rolled sheet 0 4mm in thickness 19 Screw ST3x12 6 Grid cold rolled sheet 0 5mm in thickness 20 Screw ST4x10 7 Plate cold rolled sheet 1 5mm in thickness 21 Rivet ø3 2 8 Nut M4 22 Washer ø4 9 Screw M4x10 23 Spring washer ø4 10 Bracket for heating element PA66 24 Bracket Galvanized sheet 0 8mm in thickness 11 Fan blade PA66 25 Frame PA66 12 Knob for base PC 26 Motor 220 240V 50Hz ...

Page 14: ...ic heater TDX 10 TDX 19 Overview of spare parts and spare parts list TDX 19 Note The position numbers of the spare parts differ from those describing the positions of the components mentioned in these instructions ...

Page 15: ...or electronic equipment stipulates that this equipment must not be disposed of with the household waste at the end of its life You will find collection points for free return of waste electrical and electronic equipment in your vicinity The addresses can be obtained from your municipality or local administration You can also find out about other return options that apply for many EU countries on t...

Page 16: ...e as of 2022 Relevant EU directives 2011 65 EU 2012 19 EU 2014 30 EU 2015 863 EU Applied harmonised standards EN 55014 1 2017 EN 55014 1 2017 A11 2020 Applied national standards and technical specifications EN 55014 2 2015 EN 60335 1 2012 A1 2019 EN 60335 1 2012 A2 2019 EN 60335 1 2012 A14 2019 EN 60335 2 30 2009 EN 60335 2 30 2009 A11 2012 EN 61000 3 3 2013 A1 2019 EN 62233 2008 EN IEC 61000 3 2 ...

Page 17: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: