Operating Manual – Electric hot air generator
EN
B -
2
Manual resetting
The appliance comes with a built in security device
that goes off automatically if the appliance should
happen to overheat.
If the security device should go off, let the appliance
cool down before looking for the cause of the prob-
lem. Push the “RESET” button with a small push rod
to reset the appliance.
Should the problem persist, contact the Service Centre.
Periodic storage and control
If the appliance is not used for a long period of time, it
should be cleaned before being put away. Store it in a
dry place and protect it from dust. When the appliance
is used again check to make sure that the electric
cable is not damaged. Should you have any doubts as
to the conditions of the appliance please contact the
Service Center.
The appliance should be checked at least once a year.
Only qualified personnel authorized by the manufac-
turer must carry out all repairs..
Technical Data
Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . 11-22 kW
Absorbed current . . . . . . . . . . . . . . . . . . . . . . . .32 A
Voltage . . . . . . . . . . . . . . . . . . . . . . . . . 400~V/50Hz
Air displacement . . . . . . . . . . . . . . . . . . . . 1.632 m
3
/h
Thermostat range . . . . . . . . . . . . . . . . . . . . . 0-40 °C
Size (mm) . . . . . . . . . . . . . . . . . . . . 600 x 430 x 440
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 kg
Singling out problems
PROBLEM:
CAUSE:
SOLUTION:
The appliance works
Resistance is burnt out
Replace
but does not heat
Thermostat control is broken
Replace
The appliance does
Security device was set off
Push “RESET”
not switch on
Faulty motor
Replace
Power supply interrupted
Unplug the appliance and check connection.
Limited air flow
Air duct obstructed
Clear the passage
Faulty motor
Replace