Technical Data
Notice
– Connection has to be carried out by our Technical Support.
– Observe instructions for operation and maintenance according to the operating manual of
the exhaust system.
Technical data of the corresponding exhaust systems:
Exhaust system
Hose connection ø [mm]
(inside diameter)
Volume flow [m³/h]
Pressure[Pa]
Atmos Nano
45
200
8500 (230V)
Atmos Cube
(Atmos Compact)
80
250
8500 (230V)
5800 (115V)
Atmos Mono
70
320
8500 (230V)
5800 (115V)
Atmos Mono Plus
70
320
8500 (230V)
5800 (115V)
Atmos Duo Plus
70
(2x) 320
8500 (230V)
Vent Set 300
80
max. 1000
max. 2550
Vent Set 400
100
max. 1000
max. 3800
Vent Set 500
100
max. 1200
max. 7000
Requirements for the exhaust system:
Machine
Volume flow [m³/h]
Pressure [Pa]
Speedy 100
200
1000
200 (without table exhaust)
1000 (without table exhaust)
Speedy 300
350 (with table exhaust)
1600 (with table exhaust)
300 (without table exhaust)
2500 (without table exhaust)
Speedy 360
400 (with table exhaust)
4200 (with table exhaust)
Speedy 400
400
4200
The monitoring point for flow rate and pressure is at the exhaust port at the laser machine. Pressure loss
by hoses / pipes or filter parts of the exhaust system has to be determined and additionally calculated when
selecting a proper exhaust system.
A powerful exhaust system keeps the lifetime of optics and mechanical components, the cutting quality and
the laser power interacting with the workpiece from being impaired by fumes and dust accumulating in the
machine.
34