Trotec PT 6500 S Operating Manual Download Page 2

1

Operating Manual – Air Conditioner PT 6500 S

EN

Symbols

Danger!

Warns of a hazard which can lead to injuries.

Hazardous electric voltage!

Warns of a hazard resulting from electric voltage which
can lead to injuries.

Caution!

Warns of a hazard which can lead to damage to property.

Wear safety glasses

Indicates the necessity to wear UV protection glasses.

Wear protective gloves

Indicates the necessity to wear protective gloves.

The current version of the operating manual can be found at:

Legal notice

This release replaces all previous versions. No part of this
publication may be reproduced without written permission from
Trotec. The same applies for electronically processing,
duplicating or spreading the publication. Subject to technical
changes. All rights reserved. Trademarks are used without
guarantee that they may be used freely and primarily following
the spelling of the manufacturer. Product names are registered.
Changes to construction in the interests of constant
improvements to the product, as well as changes to the shape
and colour are reserved.
The scope of delivery may vary from product images. This
document was created with all due care. Trotec accepts no
liability whatsoever for possible mistakes or omissions. © Trotec

Table of contents

Notes regarding the operating manual .................................... 1
Information about the device................................................... 2
Technical data ........................................................................ 3
Safety ..................................................................................... 4
Transport and storage............................................................. 5
Operation
................................................................................ 5
Errors and faults ..................................................................... 7
Maintenance ........................................................................... 8
Disposal.................................................................................. 11
Declaration of conformity ........................................................ 12

Notes regarding the operating manual

PT 6500 S

http://download.trotec.com/?sku=1210001070&id=1

Summary of Contents for PT 6500 S

Page 1: ...OPERATING MANUAL AIR CONDITIONER EN PT 6500 S TRT BA PT6500S TC 003 EN...

Page 2: ...uplicating or spreading the publication Subject to technical changes All rights reserved Trademarks are used without guarantee that they may be used freely and primarily following the spelling of the...

Page 3: ...erant cools down the air coming from the room and in doing so absorbs the heat The thusly cooled air is introduced to the room where the device is positioned via the fan Accumulating condensate is dis...

Page 4: ...ensions external heat exchanger height x width x depth 1200 mm x 815 mm x 360 mm 510 mm x 650 mm x 320 mm Maximum distance between basic device and external heat exchanger 30 m Minimum distance of ext...

Page 5: ...the basic device outdoors Do not place any objects e g wet clothing on the device for drying Any unauthorised changes modifications or alterations to the device are forbidden Personnel qualifications...

Page 6: ...s when laying the power cable or other lines Make sure that no curtains or other objects interfere with the air flow Ensure that extension cords are completely unrolled Installation of the external he...

Page 7: ...the device I stands for cooling mode II stands for ventilation mode Shutdown 1 Use the ON OFF switch 18 to switch the device off 2 Remove the mains plug from the mains socket 3 Disconnect all connecti...

Page 8: ...heat exchanger for proper fit The device automatically performs a reset The warning message HIPS is displayed Check the connection lines leading to the external heat exchanger for proper fit Check th...

Page 9: ...Replace air filter x Check for damage x Check attachment screws x x Test run x Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign o...

Page 10: ...the inside of the device 1 Remove the air filter 2 Use a torch to illuminate the openings of the device 3 If you see a thick layer of dust have the inside of the device cleaned by a specialist compan...

Page 11: ...edges of the air filter must not be rounded or misshaped Before reinserting the air filter ensure that it is dry and is not damaged Observe the maintenance intervals to replace the air filter in due...

Page 12: ...waste but must be disposed of professionally in accordance with Directive 2002 96 EC of the European Parliament and of the Council of 27 January 2003 on waste electrical and electronic equipment WEEE...

Page 13: ...aintenance etc or unauthorized changes of the factory supplied device version this declaration loses its legal validity Device version Air Conditioner Series PT Year of manufacture as of June 2014 App...

Page 14: ......

Page 15: ......

Page 16: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...