Operating Manual – Air Conditioner PT 6500 S
2
Device description
The primary purpose of the device is room cooling. Moreover, the
device also provides the opportunity of air circulation without
cooling effect.
Operating the device is effected via the control panel (1) at the
device.
The device is an air conditioner with split cooling circuits. The
refrigerant circuit of the basic device (2) is self-contained. For the
dissipation of warmth it is emitted via a heat exchanger to a
second cooling circuit. A second circuit transports warmed
water / glycol mixture to the external heat exchanger (7) to cool it
down again.
The unit cools the room air by withdrawing warmth. The
refrigerant cools down the air coming from the room and in doing
so absorbs the heat. The thusly cooled air is introduced to the
room, where the device is positioned, via the fan.
Accumulating condensate is discharged via a separate
hose (3, 11) to the external heat exchanger in order to evaporate
there.
Device depiction
Information about the device
No.
Operating element
1
control panel
2
basic device
3
condensation hose
4
line to the external heat exchanger (red)
5
tank with screw cap
6
fan
7
external heat exchanger
8
mains connection external heat exchanger
9
connection for line to basic device (blue)
10
connection for line from basic device (red)
11
condensation hose connection
12
line from the external heat exchanger (blue)
13
mains cable to external heat exchanger
14
mains connection with power plug
15
air inlet
16
louvre and air outlet
8