Trotec PCPS 10-1100 Original Instructions Manual Download Page 5

EN

4

compressor PCPS 10-1100

Do not touch hot device parts.

 Please note that the

compressor and the lines can reach high temperatures
during operation and cause burns even after use of the
device. Allow the device to cool down after use. Wear
protective gloves to protect yourself against burns.

Always wear safety glasses and a respiratory mask
when using the blow-out gun.

 

Stirred up or blown off particles can easily be inhaled or
cause eye injuries.

Wear appropriate hearing protection during
operation.

 The sound pressure level L

pA

 of this device

amounts to 94.1 dB(A). Without appropriate hearing
protection this can cause hearing loss.

Only use accessories and feed hoses equipped with a
quick coupling. 

Feed hoses connected otherwise may accidentally come
loose and cause injuries due to whipping.

Do not directly breathe in the exhaust air coming from
the device.

 The exhaust air may contain contaminations

such as water, oil or metal particles from inside the
compressor. This can cause damages to health.

Make sure that the used socket is connected to a
circuit provided with sufficient overvoltage protection!

Please refer to the technical data for the corresponding
information. If used out of doors, the circuit should be
secured by means of a residual current device (RCD) with a
release current of maximally 30 mA.

Ensure the secure footing and stable positioning of the
device.

 During operation the compressor shall always be

placed on its rubber feet or the bottom side. Never exceed
the inclination angle of 10° (vertical pos.) or 15° (horizontal
pos.).

Intended use

Only use the device 

PCPS 10-1100

:

for inflating car tyres, bicycle tyres, inflatable toys, sports
equipment and beach items

for measuring the current pressure level of an inflatable
object

for generating compressed air for pneumatic tools

whilst adhering to the technical data.

Info

Please note that the pressure gauge is not calibrated.

We recommend using the power tool with original Trotec
accessories.

Improper use

The device 

PCPS 10-1100

 is not intended for commercial use.

Do not use the device in continuous operation.
The device must not be used for inflating truck/tractor tyres or
other items the specified pressure of which exceeds the
maximum operating pressure of the compressor.
The device must not be used in the food sector or for
pharmaceutical and medical purposes.
Do not use the device for filling scuba tanks with compressed
air.

Personnel qualifications

People who use this device must:

have read and understood the operating manual, especially
the Safety chapter.

Personal protective equipment

Wear hearing protection.

Excessive noise can lead to hearing loss.

Wear eye protection. 

With it you protect your eyes from splintering, falling
and flying pieces which could cause injuries.

Wear a protective mask.

It saves you from inhaling harmful dusts generated
when processing workpieces.

Wear protective gloves.

They protect your hands from burns, crushing injuries
and skin abrasions.

Residual risks

Warning of electrical voltage

Electric shock from insufficient insulation.
Check the device for damages and proper functioning
before each use.
If you notice damages, no longer use the device.
Do not use the device when the device or your hands
are damp or wet!

Warning of electrical voltage

Work on the electrical components must only be
carried out by an authorised specialist company!

Warning of electrical voltage

Before any work on the device, remove the mains plug
from the mains socket!
Hold onto the mains plug while pulling the power cable
out of the mains socket.

Summary of Contents for PCPS 10-1100

Page 1: ...TRT BA PCPS10 1100 TC 002 EN PCPS 10 1100 EN ORIGINAL INSTRUCTIONS COMPRESSOR...

Page 2: ...r hearing protection Information marked with this symbol indicates that you should wear hearing protection Wear safety glasses Information marked with this symbol indicates that you should wear eye pr...

Page 3: ...a power tool outdoors use an extension cord suitable for outdoor use Use of a cord suitable for outdoor use reduces the risk of electric shock If operating a power tool in a damp location is unavoida...

Page 4: ...s maintained Device specific safety warnings for compressors and blow out guns Do not use the device in potentially explosive rooms Ensure that the side of the device where the air inlet is found is k...

Page 5: ...nd beach items for measuring the current pressure level of an inflatable object for generating compressed air for pneumatic tools whilst adhering to the technical data Info Please note that the pressu...

Page 6: ...distance from heat sources Note If you store or transport the device improperly the device may be damaged Note the information regarding transport and storage of the device Note The device is not sui...

Page 7: ...ation 1 Transport handle 2 On off switch with protective cover 3 Storage compartment for compressed air hose 4 Compressed air hose with quick coupling 5 3 fold nozzle attachments 6 Ball needle 7 Unive...

Page 8: ...ce being processed Transport and storage Note If you store or transport the device improperly the device may be damaged Note the information regarding transport and storage of the device Transport Bef...

Page 9: ...m the system 2 Pull back the sleeve 28 at the quick coupling 21 of the compressed air hose 4 Hold the quick coupling steady in your hand to prevent uncontrolled release 28 3 Take the released compress...

Page 10: ...as follows The device is switched off 1 If the compressed air gun is already connected to the compressor disconnect it from the compressor first see chapter Disconnecting the compressed air gun 2 Use...

Page 11: ...scale for psi Measures the pressure in psi 27 Indicator scale for bar Measures the pressure in bar 28 Indicator needle Indicates the current pressure value in psi and bar Checking the pressure 1 Conn...

Page 12: ...r becomes sluggish and can be difficult or impossible to start up Do not use the device at an temperatures below 5 C The device is running but there is no apparent inflation The pressure gauge shows n...

Page 13: ...after cleaning Warning of electrical voltage There is a risk of a short circuit due to liquids penetrating the housing Do not immerse the device and the accessories in water Make sure that no water o...

Page 14: ...l Product PCPS 10 1100 Product type compressor Year of manufacture as of 2018 Guaranteed sound power level LWA 97 dB A Relevant EU directives 2000 14 EC 8 May 2000 2005 88 EC 14 Dec 2005 2011 65 EU 1...

Page 15: ......

Page 16: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...