background image

9

EN

compressor PCPS 10-1100

Exchanging the nozzle

To blow up inflatable items, you can connect the following
nozzles to the compressed-air hose via the supplied nozzle
adapter (9).

No.

Description

23

To be used with inflatables fitted with a vent valve

24

To be used with inflatables fitted with a screw-on valve

25

To be used with standard valves with an inner diameter
of 8 mm or more

To connect one of the nozzles via the nozzle adapter, please
proceed as follows:

ü

The device is switched off.

1. Push the quick-release lever (22) at the hose (15) of the

compressed-air gun and insert the nozzle adapter (9).

2. Attach the desired nozzle (23, 24, 25) to the nozzle

adapter (9).

23

9

24
25

Connecting the blow-out adapter

To remove dust and dirt in poorly accessible locations, use the
blow-out adapter (16).
To connect the blow-out adapter (16), please proceed as
follows:

ü

The device is switched off.

1. If the compressed-air gun is already connected to the

compressor, disconnect it from the compressor first (see
chapter Disconnecting the compressed-air gun).

2. Use an open-end wrench (SW14) to disconnect the

hose (15) from the compressed-air gun (12) by unscrewing
it counter-clockwise.

3. Fit the blow-out adapter (16) into the internal thread and

fasten it clockwise.

4. Connect the compressed-air gun to the compressor again

(see chapter Connecting the compressed-air gun).

Operation

Tips and notes on handling the compressor

General information:

Keep the venting slots clear to prevent the motor from
overheating.

The device is not suitable for continuous operation. Over a
period of 10 minutes, do not use the device for more than
1.5 minutes in continuous operation. Allow the device to
cool down for the remaining time.

Only use intact, flawless valve adapters.

Do not use the device at temperatures below +5 °C, since
the motor becomes sluggish and can be difficult or
impossible to start up at these temperatures.

Summary of Contents for PCPS 10-1100

Page 1: ...TRT BA PCPS10 1100 TC 002 EN PCPS 10 1100 EN ORIGINAL INSTRUCTIONS COMPRESSOR...

Page 2: ...r hearing protection Information marked with this symbol indicates that you should wear hearing protection Wear safety glasses Information marked with this symbol indicates that you should wear eye pr...

Page 3: ...a power tool outdoors use an extension cord suitable for outdoor use Use of a cord suitable for outdoor use reduces the risk of electric shock If operating a power tool in a damp location is unavoida...

Page 4: ...s maintained Device specific safety warnings for compressors and blow out guns Do not use the device in potentially explosive rooms Ensure that the side of the device where the air inlet is found is k...

Page 5: ...nd beach items for measuring the current pressure level of an inflatable object for generating compressed air for pneumatic tools whilst adhering to the technical data Info Please note that the pressu...

Page 6: ...distance from heat sources Note If you store or transport the device improperly the device may be damaged Note the information regarding transport and storage of the device Note The device is not sui...

Page 7: ...ation 1 Transport handle 2 On off switch with protective cover 3 Storage compartment for compressed air hose 4 Compressed air hose with quick coupling 5 3 fold nozzle attachments 6 Ball needle 7 Unive...

Page 8: ...ce being processed Transport and storage Note If you store or transport the device improperly the device may be damaged Note the information regarding transport and storage of the device Transport Bef...

Page 9: ...m the system 2 Pull back the sleeve 28 at the quick coupling 21 of the compressed air hose 4 Hold the quick coupling steady in your hand to prevent uncontrolled release 28 3 Take the released compress...

Page 10: ...as follows The device is switched off 1 If the compressed air gun is already connected to the compressor disconnect it from the compressor first see chapter Disconnecting the compressed air gun 2 Use...

Page 11: ...scale for psi Measures the pressure in psi 27 Indicator scale for bar Measures the pressure in bar 28 Indicator needle Indicates the current pressure value in psi and bar Checking the pressure 1 Conn...

Page 12: ...r becomes sluggish and can be difficult or impossible to start up Do not use the device at an temperatures below 5 C The device is running but there is no apparent inflation The pressure gauge shows n...

Page 13: ...after cleaning Warning of electrical voltage There is a risk of a short circuit due to liquids penetrating the housing Do not immerse the device and the accessories in water Make sure that no water o...

Page 14: ...l Product PCPS 10 1100 Product type compressor Year of manufacture as of 2018 Guaranteed sound power level LWA 97 dB A Relevant EU directives 2000 14 EC 8 May 2000 2005 88 EC 14 Dec 2005 2011 65 EU 1...

Page 15: ......

Page 16: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: