background image

15

EN

Operating manual – angle grinder PAGS 10-230

Available accessories

Warning

Only use accessories and additional equipment
specified in the operating manual.
Using insertion tools or accessories other than those
specified in the operating manual may cause a risk of
injury.

Designation

Article number

Cutting disc diamond Ø 230 mm

6.225.001.221

Cutting disc metal Ø 230 mm

6.225.001.211

Errors and faults

The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
Troubleshooting tasks which require the housing to be opened
must only be carried out by a specialist dealer or by Trotec.

Slight smoke or odour are emitted during first use:

This is not a fault. These phenomena disappear after a
brief runtime.

The device does not start:

Check the power connection.

Check the power cable and mains plug for damages.

Check the on-site fusing.

Info

Wait for at least 10 minutes before switching the
device back on.

The cutting disc is loose:

Check whether you are using a cutting disc that is suited
for this device.

Make sure that the mounting flange (13) is firmly locked in
place in the designated recesses.

Make sure that the cutting disc (14) sits flush on the
mounting flange (13) without clearance.

Make sure that the flat side of the clamping nut (15) rests
on the cutting disc (14).

The guard is loose:

Make sure that the coded projections (11) are firmly locked
in place in the designated groove.

Make sure that the locking lever (12) is folded in
completely.

If necessary, tighten the adjusting screw (10).

The cutting disc does not move although the motor is
running:

Make sure that the clamping nut (15) is firmly tightened,
see chapter Tool change.

Make sure that there is no workpiece debris blocking the
drive. Remove the blockages, if any.

Make sure that the cutting disc is not jammed in the
workpiece.

The motor slows down:

Check whether the device is overloaded by the workpiece.

Reduce the pressure applied on the workpiece.

Check whether the workpiece is suitable for the tasks to
be carried out.

Check whether the carbon brushes (19) are worn. If
necessary, replace them; see chapter Changing the carbon
brushes.

The cutting disc experiences difficulties penetrating the
material to be processed or the cutting performance is
insufficient:

Check whether the chosen cutting disc is suitable for the
material to be processed.

If the cutting disc is worn, replace it with a new one.

The device becomes hot:

Check whether the cutting disc is suitable for the tasks to
be carried out.

Make sure not to exert too much pressure on the device
during operation.

Keep the venting slots clear to prevent the motor from
overheating.

Wait for at least 10 minutes before switching the device
back on.

Notice

Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.

Your device still does not operate correctly after these
checks?

Please contact the customer service. If necessary, bring the
device to an authorized specialist electrical company or to
Trotec for repair.

Summary of Contents for PAGS 10-230

Page 1: ...TRT BA PAGS10 230 TC 001 EN PAGS 10 230 EN OPERATING MANUAL ANGLE GRINDER...

Page 2: ...l Information marked with this symbol indicates that the operating manual must be observed Wear head protection Information marked with this symbol indicates that you should wear protective headgear W...

Page 3: ...cause you to lose control General Power Tool Safety Warnings Electrical safety Power tool or power adapter plugs must match the outlet Never modify the plug in any way Do not use any adapter plugs wi...

Page 4: ...rly maintained power tools Keep cutting tools sharp and clean Properly maintained cutting tools with sharp cutting edges are less likely to bind and are easier to control Use the power tool accessorie...

Page 5: ...clothing pulling the accessory into your body Regularly clean the power tool s air vents The motor s fan will draw the dust inside the housing and excessive accumulation of powdered metal may cause el...

Page 6: ...ving away from your body the possible kickback may propel the spinning wheel and the power tool directly at you When wheel is binding or when interrupting a cut for any reason switch off the power too...

Page 7: ...could cause injuries Residual risks Warning of electrical voltage Electric shock from insufficient insulation Check the device for damages and proper functioning before each use If you notice damages...

Page 8: ...transport and storage of the device in the operating manual Behaviour in the event of an emergency 1 In an emergency disconnect the device from the mains feed in Switch the device off and disconnect t...

Page 9: ...nal handle 1 x Pin type face wrench 1 x Clamping nut 1 x Transport case 1 x Manual Technical data Parameter Value Model PAGS 10 230 Mains connection 1 N PE 230 V 50 Hz Power consumption 2 kW Rated spe...

Page 10: ...included in the scope of delivery in order to protect the device from external influences Before transporting the device proceed as follows Switch off the device Hold onto the mains plug while pulling...

Page 11: ...ge Before any work on the device remove the mains plug from the mains socket Hold onto the mains plug while pulling the power cable out of the mains socket Caution If you detect damage at the guard st...

Page 12: ...al is preassembled Warning of electrical voltage Before any work on the device remove the mains plug from the mains socket Hold onto the mains plug while pulling the power cable out of the mains socke...

Page 13: ...cesses 14 13 5 Put the cutting disc 14 on the mounting flange 13 The labelling must point to the device Make sure that the cutting disc hole fits the mounting flange without clearance Do not use any r...

Page 14: ...disc for correct fit Only use tools which are approved for the device used Before every application make sure that you have selected the correct tool for the intended use Check the tool in the tool h...

Page 15: ...ng 7 To switch the device off let go of the on off switch 5 Caution The disc keeps running after the device has been switched off Risk of injury 5 Rotating the handle The handle 4 can be rotated by 90...

Page 16: ...are firmly locked in place in the designated groove Make sure that the locking lever 12 is folded in completely If necessary tighten the adjusting screw 10 The cutting disc does not move although the...

Page 17: ...uids can enter the housing Clean the device with a soft damp and lint free cloth Ensure that no moisture enters the housing Protect electrical components from moisture Do not use any aggressive cleani...

Page 18: ...ntact connector 17 from the pin 17 3 Press the pressure spring 18 down and take the worn carbon brush 19 out of the guide 18 19 4 Hold the pressure spring 18 down and insert a new carbon brush 20 into...

Page 19: ...collection points for free return of waste electrical and electronic equipment in your vicinity The addresses can be obtained from your municipality or local administration For further return options...

Page 20: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: