15
EN
Operating manual – angle grinder PAGS 10-230
Available accessories
Warning
Only use accessories and additional equipment
specified in the operating manual.
Using insertion tools or accessories other than those
specified in the operating manual may cause a risk of
injury.
Designation
Article number
Cutting disc diamond Ø 230 mm
6.225.001.221
Cutting disc metal Ø 230 mm
6.225.001.211
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
Troubleshooting tasks which require the housing to be opened
must only be carried out by a specialist dealer or by Trotec.
Slight smoke or odour are emitted during first use:
•
This is not a fault. These phenomena disappear after a
brief runtime.
The device does not start:
•
Check the power connection.
•
Check the power cable and mains plug for damages.
•
Check the on-site fusing.
Info
Wait for at least 10 minutes before switching the
device back on.
The cutting disc is loose:
•
Check whether you are using a cutting disc that is suited
for this device.
•
Make sure that the mounting flange (13) is firmly locked in
place in the designated recesses.
•
Make sure that the cutting disc (14) sits flush on the
mounting flange (13) without clearance.
•
Make sure that the flat side of the clamping nut (15) rests
on the cutting disc (14).
The guard is loose:
•
Make sure that the coded projections (11) are firmly locked
in place in the designated groove.
•
Make sure that the locking lever (12) is folded in
completely.
•
If necessary, tighten the adjusting screw (10).
The cutting disc does not move although the motor is
running:
•
Make sure that the clamping nut (15) is firmly tightened,
see chapter Tool change.
•
Make sure that there is no workpiece debris blocking the
drive. Remove the blockages, if any.
•
Make sure that the cutting disc is not jammed in the
workpiece.
The motor slows down:
•
Check whether the device is overloaded by the workpiece.
•
Reduce the pressure applied on the workpiece.
•
Check whether the workpiece is suitable for the tasks to
be carried out.
•
Check whether the carbon brushes (19) are worn. If
necessary, replace them; see chapter Changing the carbon
brushes.
The cutting disc experiences difficulties penetrating the
material to be processed or the cutting performance is
insufficient:
•
Check whether the chosen cutting disc is suitable for the
material to be processed.
•
If the cutting disc is worn, replace it with a new one.
The device becomes hot:
•
Check whether the cutting disc is suitable for the tasks to
be carried out.
•
Make sure not to exert too much pressure on the device
during operation.
•
Keep the venting slots clear to prevent the motor from
overheating.
•
Wait for at least 10 minutes before switching the device
back on.
Notice
Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.
Your device still does not operate correctly after these
checks?
Please contact the customer service. If necessary, bring the
device to an authorized specialist electrical company or to