EN
12
local air conditioner PAC 3550 PRO
Remote control
All settings of the device can also be made using the remote
control included in the scope of delivery.
Insert suitable batteries in the remote control (see chapter
Technical annex).
Info
After a longer period of non-use, the remote control
will switch to standby mode. Standby mode can be
terminated by pressing the
POWER
button on the
remote control Please note that the device
automatically takes over the current settings from the
remote control.
18
29
30
23
28
35
34
19
24
21
31
20
22
26
33
32
36
No.
Designation
Meaning
18
TIMER
button
Automatic switch-on
timer function in
increments of 1 hour (1 h to 24 h)
Automatic switch-off
timer function in
increments of 1 hour (1 h to 24 h)
19
FAN
button
Setting the fan speed in 3 stages:
High, Medium and Low
Only enabled in
cooling
and
ventilation
mode.
20
UP
button
Increasing the target temperature
(17 °C to 30 °C) or
the number of hours of the timer (1 h
to 24 h).
21
Segment display
Display of current room temperature
when in operation
Display of target temperature while
setting it
Display of timer
Display of error codes
22
DOWN
button
Decreasing the target temperature
(17 °C to 30 °C) or
the number of hours of the timer (1 h
to 24 h).
No.
Designation
Meaning
23
MODE
button
Selection button for the mode of
operation
automatic operation
cooling
ventilation
dehumidification
24
POWER
button
Power button:
Switching the device on or off
26
Timer
indication
Timer active
28
Battery
indication Charging status of the batteries for
the remote control
29
Operating mode
indication
Auto =
automatic mode
Cool =
cooling
Fan =
ventilation
30
Fan speed
indication
Low =
Medium =
High =
31
°C / °F
button
Switching temperature indication
between °C and °F
32
SWING
button
Adjusting the position of the
ventilation flaps
33
Operating mode
indication
Dry =
dehumidification
34
Transmission
indication
Indicates transmission to the device
when the button is pressed
35
Remote control
transmitter /
receiver
Communication between device and
remote control
36
Swing function
indication
Swing function active
Swing function
The swing function can only be activated via the remote control.
Using the swing function, you can adjust the position of the
ventilation flaps or activate continuous movement of the
ventilation flaps.
1. Press the
SWING
button (32).
ð
The ventilation flaps move up and down continuously.
ð
The
swing function
indication (36) is illuminated.
2. Press the
SWING
button (32) again to stop the ventilation
flaps in a certain position and to switch off the swing
function.
ð
The
swing function
indication (36) disappears.