Activities required after maintenance
If you want to continue using the device:
•
Leave the device to rest for 12 - 24 hours, so the
refrigerant can accumulate within the compressor. Wait
12 - 24 hours before switching the device back on! Acting
contrary might lead to compressor damage and a
malfunctioning device. If so, any warranty claims will be
voided.
•
Reconnect the device to the mains.
If you do not intend to use the device for a considerable time:
•
Store the device according to the Storage chapter.
Technical annex
Technical data
Model
PAC 2010 S
Cooling capacity
2 kW
Dehumidification performance
1 l/h
Operating temperature
15 °C to 35 °C
Temperature setting range
15 °C to 31 °C
Max. air volume flow
230 m
3
/h
Mains connection
1/N/PE~ 220 V - 240 V / 50 Hz
Nominal current
3.5 A
Power input (cooling operation)
0.8 kW
Sound pressure level
54 dB(A)
Refrigerant
R410A
Amount of refrigerant
320 g
GWP factor
2088
CO
2
equivalent
0.67 t
Dimensions (length x width x height)
310 x 310 x 640 (mm)
Minimum distance to walls and other
objects:
top (A):
rear (B):
sides (C):
front (D):
50 cm
50 cm
50 cm
50 cm
Weight
21 kg
Wiring diagram