• When positioning the device in wet areas such as
laundries, bath rooms or the like, secure the
device locally with an RCD (Residual Current
protective Device) which complies with the
appropriate regulations.
• Ensure that extension cords are completely
unrolled.
Notes regarding the dehumidifying capacity
The dehumidifying capacity depends on:
• the spatial composition of the room
• the room temperature
• the relative humidity
The higher the room temperature and relative
humidity, the higher the dehumidifying capacity.
For using in living rooms, a relative humidity of
approx. 50-60 % is sufficient. In store rooms and
archives, the humidity should not exceed
approx. 50 %.
Operating elements
Display
No.
Operating element
8
Condensation tank full indicator light (red)
9
Display
10
Mains switch:
Switches the device on and off.
11
"TIMER" button
12
Arrow button down
13
Arrow button up
14
"FAN SPEED" button
TANK FULL
ROOM HUMIDITY
88
88
%RH
°C
STOP
(%)
80
70
60
50
40
30
ROOM TEMP
SETTING MODE
°C
10
8
11
12
13
14
9
No.
Operating element
15
Condensation tank full or not correctly inserted.
16
Desired level of humidity (30-80 %)
17
Fan speed:
One drop: low fan speed
Two drops: high fan speed
18
"Defrost" symbol
19
"Timer" symbol with operating time (1-12 hours)
20
Room temperature
21
Current humidity
88
88
%RH
°C
STOP
(%)
80
70
60
50
40
30
°C
16
19
20
21
17
18
15