10. Technical data

Technical data

DL200P

Detectable 
measured values

internal sensors

air temperature (°C / °F), dew point temperature (°C / °F), 

relative humidity % RH, absolute humidity g/m³

external 
measured value sensor

surface temperature (°C / °F), material temperature (°C / °F), 

air temperature (°C / °F), wood moisture (digits), 

building moisture (digits)

Sensor internal 
(temperature)

Operating principle

NTC

Measuring range

-20 °C to + 50 °C

Accuracy

± 0.3 °C (0…40 °C), otherwise 0.5 °C

Screen resolution

0.1 °C

Sensor internal 
(humidity)

Operating principle

capacitive

Measuring range

0 to 100 % RH

Accuracy

±2 % RH

Screen resolution

0.1 % RH

Sensor external (temperature)

see technical data for the TS 910 sensor

external electrodes 
(wood and building 
moisture)** 

Operating principle

Resistance measurement process

Measuring range

15 to 100 digits

Accuracy*

± 3 digits

Screen resolution*

1 digit

Memory organisation

Sensing interval

10 / 30 s, 1 / 10 / 12 / 15 / 30 min., 1 / 3 / 6 / 12 / 24 h

Saving interval

1 / 10 / 12 / 15 / 30 min., 1 / 3 / 6 / 12 / 24 h

Data storage

integrated Flash memory with 16 MB capacity (approx. 3,200,000 measured values)

Data recording

up to 20 simultaneous measuring channels

Configuration 
and dimensions

LCD display

W 90 x H 64 mm

Housing

Plastic

Dimensions

L 166 x W 32 x H 78 mm

Weight

approx. 250 g

Interfaces

USB, LAN

Connection for external sensors

2 x 3.5 mm plug socket 

Connection for external electrodes

2 x BNC plug socket 

Power supply

internal

4 x LR6 AA batteries, battery life > 1 year

external

USB

Permissible operating 
ambient conditions

Air temperature

-20 °C to +50 °C

Relative humidity

0 to 95 % RH, < 20 g / m³ (non-condensing)

Height

10,000 m above sea level

Scope of supply

Standard

Measuring device, CD-ROM with SmartGraph PC software for representing 

the evaluation of measured values graphically and numerically and operating manual, 

USB connection cable, batteries

Optional

external temperature sensor TS910, 

external electrodes for measuring wood 

and building moisture

*       in the range 20 … 80 digits 

**     external measuring electrodes with BNC connector for measuring resistance of wood and building moisture; 

       an additional TC 20 connecting cable is necessary for connecting. 

Summary of Contents for DL200P

Page 1: ...DL200P EN TRT BA DL200P WM 02 EN OPERATING MANUAL DATA LOGGER ...

Page 2: ...etected at variable selectable recording or request intervals then saved and transmitted to a connected PC The measuring device may only be used for this intended use while complying with specified technical data Any other use is considered misuse and contrary to the intended use The product must not be disposed of with household waste Dispose of this device in a manner according to the relevant l...

Page 3: ...for active measured value recording Display for inactive measured value recording Display for date Display for time Mode selection button Data logger with internal sensors and additional connections for four external measured value sensors 3 5 mm plug socket for external temperature sensor 1 T1ext 3 5 mm plug socket for external temperature sensor 2 T2ext BNC connector for external building moistu...

Page 4: ...ger to your PC via the USB cable provided in the scope of supply The measuring device is automatically detected by the operating system Alternatively you can configure your data logger via a LAN connection over your local network if the network function is enabled Further information about the network function is provided in chapter 6 2 2 Start the SmartGraph software The program automatically det...

Page 5: ...ly configured with one button operation by using the mode selection button on your data logger You can restrict the one button operation with the mode selection button from your software if necessary key lock It is not possible to operate your data logger with the mode selection button in this case 6 1 Switching on and off When power is being supplied the data logger cannot completely switch off b...

Page 6: ...nd not connected to an external power supply it automatically deactivates the network function after 12 minutes pass without communicating with the network In this case the network function must be restarted by an external power supply either manually or automatically b When using the data logger in LAN mode the power should thus be supplied by the USB power supply In the optionally available PoE ...

Page 7: ...ing because it is not possible to calculate these values in the software m The dew point temperature is its own channel group and thus can not be calculated from the measured values of other channel groups retrospectively during a later evaluation So when organising the memory select the necessary dew point temperature measuring channels for recording as needed The specifications for type duration...

Page 8: ...eresis can be set by which the measured value must return to the valid range to switch off the alarm Example display for an alarm result of the measuring channel shown in the first measured value row Alarm display Upper alarm limit value Valid value corridor good range Lower alarm limit value flashing static Logging mode Reading the measured value memory 8 Alarm function 8 3 Acoustic alarm If an a...

Page 9: ...e is not possible and it does not respond to requests from the Smart Graph3 software After memory has been completely deleted FOMA FLSH 100 is shown on the display Afterwards the display returns to normal operation Further detailed information about using the software is provided in the software manual which you can open from the help function of the Smart Graph software Display for deleting measu...

Page 10: ...12 15 30 min 1 3 6 12 24 h Data storage integrated Flash memory with 16 MB capacity approx 3 200 000 measured values Data recording up to 20 simultaneous measuring channels Configuration and dimensions LCD display W 90 x H 64 mm Housing Plastic Dimensions L 166 x W 32 x H 78 mm Weight approx 250 g Interfaces USB LAN Connection for external sensors 2 x 3 5 mm plug socket Connection for external ele...

Page 11: ...ight 85 g Type of protection IP65 Connection 3 5 mm plug socket In the event of a sensor error the following codes may appear on one of the three LCD rows instead of the measured value E 2C Initialisation error at the sensor E 27 Faulty calibration data E 36 Channel disabled e g channel configured in the LCD but sensor logged off or removed E 50 Value to be displayed too large to fit on display E ...

Page 12: ...Trotec GmbH Grebbener Straße 7 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: