condenser dryer DH 105 S / DH 115 S
•
Make sure that no curtains or other objects interfere with
the air flow.
•
When positioning the device, particularly in wet areas,
secure it locally with an RCD (residual current device)
which complies with the respective regulations.
Inserting the air filter
Note
Do not operate the device without an inserted air filter!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.
•
Make sure that the air filter is installed before switching
the device on.
A.
B.
C.
Positioning the condensation drain hose
For continuous operation or unattended dehumidification, please
connect the supplied condensation drain hose to the device.
ü
A suitable hose (diameter: 15 mm) is ready for use.
ü
The device is switched off.
1. Connect the condensation drain hose to the condensation
hose connection (6) at the device.
2. Make sure that the condensation drain hose is properly
connected to the device and free of damage.
3. Depending on the application, position the end of the
condensation drain hose as follows:
ð
Place a sufficiently dimensioned container (at least
90 litres) beside the device and insert the hose end.
Check the filling level of the container regularly.