background image

B - 6

Operating manual - Food thermometer BP5F

EN

Temperature measurement

1. Press any button to switch on the device.
2. Press  the  "MODE"  button  (6)  to  switch  between

measurement with infrared, the temperature probe
and the timer function.
The symbols (11, 12) indicate which measurement
type is selected.

Infrared

• Vapours and smoke can influence the measurement.
• Ensure  that  the  surface  to  be  measured  is  free  of

dust, dirt, ice or similar substances.

• To be able to gain exact measurement results on sur-

faces which reflect heavily, stick matt masking tape
to the surface or apply matt black paint with a very
high and known level of emissivity.

• Note the 20:1

 

ratio of the distance to the measuring

spot size. The larger the distance to the object, the
larger the measuring spot and hence, the less precise
the measured result.

3. Point the device at the object to be measured and

hold down the "MEAS" (3) button. 
– The device turns on and carries out a measure-

ment. The "SCAN" symbol (19) appears in the dis-
play. The current measured value is shown.

4. Release the "MEAS" button (3).

– The  device  stops  measuring.  The  "HOLD"

symbol (20) appears in the display. The last value
measured is shown.

Operation

80:4

40:2

20:1

2032:102

1016:51

508:25 

inch

mm

Summary of Contents for BP5F

Page 1: ...TRT BA BP5F TC 002 INT BP5F BEDIENUNGSANLEITUNG OPERATING MANUAL MANUEL D UTILISATION INT DE EN FR IT NL ES PT PL TR DA FI NO SV RU...

Page 2: ...permission from Trotec The same applies for electroni cally processing duplicating or spreading the publicati on Subject to technical changes All rights reserved Trademarks are used without guarantee...

Page 3: ...nual especially the Safety chapter Improper use The device must not be pointed at people Trotec accepts no liability for damages resulting from improper use In such a case entitlements to a warranty a...

Page 4: ...range 40 C to 280 C 40 F to 536 F Temperature probe accuracy below 5 C 23 F 1 C 1 8 F between 5 C and 65 C 23 F and 150 F 1 C 1 8 F above 65 C 150 F 1 Infrared accuracy below 40 C to 4 C 40 F bis 39 2...

Page 5: ...mperature ranges below 4 C and above 60 C is an important way of preventing the development and reproduction of harmful microorganis ms On the other hand temperatures between 4 C and 60 C can promote...

Page 6: ...minimum value from the last measure ment or Time for the timer function 14 Set time for the timer function 15 Display of the maximum value 16 Green LED Temperature above 60 C 140 F 17 Red LED Tempera...

Page 7: ...lect heavily stick matt masking tape to the surface or apply matt black paint with a very high and known level of emissivity Note the 20 1 ratio of the distance to the measuring spot size The larger t...

Page 8: ...hold the MODE button 6 for 3 seconds to switch between seconds minutes and hours 5 Press the TIMER button 2 to set the correspon ding value 6 Press the MEAS button 3 to start the timer The timer rema...

Page 9: ...amp and lint free cloth Ensure that no moisture enters the housing Do not use any sprays solvents alcohol based cleaning agents or abrasive cleaners Only use clean water to moisten the cloth Disinfect...

Page 10: ...rective 2006 95 EC Annex III Section B and the EC Directive 2004 108 EC about electromagnetic compatibility We hereby declare that the food thermometer BP5F was de signed developed and produced in com...

Page 11: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: