Trotec BA06 Operating Manual Download Page 2

2

EN

vane anemometer BA06

Table of contents

Notes regarding the operating manual................................. 2

Safety ..................................................................................... 2

Information about the device................................................ 3

Transport and storage........................................................... 5

Operation ............................................................................... 5

Maintenance and repair ........................................................ 6

Errors and faults.................................................................... 6

Disposal ................................................................................. 6

Notes regarding the operating manual

Symbols

Warning of electrical voltage

This symbol indicates dangers to the life and health of
persons due to electrical voltage.

Warning

This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.

Caution

This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.

Note

This signal word indicates important information 
(e.g. material damage), but does not indicate hazards.

Info

Information marked with this symbol helps you to carry
out your tasks quickly and safely.

Follow the manual

Information marked with this symbol indicates that the
operating manual must be observed.

You can download the current version of the operating manual
and the EU declaration of conformity via the following link:

BA06

https://hub.trotec.com/?id=43621

Safety

Read this manual carefully before starting or using the
device. Always store the manual in the immediate vicinity
of the device or its site of use!

Warning
Read all safety warnings and all instructions.

Failure to follow the warnings and instructions may
result in electric shock, fire and / or serious injury.

Save all warnings and instructions for future
reference.

This appliance can be used by children aged from
8 years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or
instruction concerning use of the appliance in a safe
way and understand the hazards involved.
Children shall not play with the appliance. Cleaning and
user maintenance shall not be made by children
without supervision.

Do not use the device in potentially explosive rooms.

Do not use the device in aggressive atmosphere.

Do not immerse the device in water. Do not allow liquids to
penetrate into the device.

The device may only be used in dry surroundings and must
not be used in the rain or at a relative humidity exceeding
the operating conditions.

Protect the device from permanent direct sunlight.

Do not expose the device to strong vibrations.

Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.

Do not open the device.

Observe the storage and operating conditions as given in
the Technical data chapter.

Summary of Contents for BA06

Page 1: ...TRT BA BA06 TC2019 40 002 EN BA06 EN OPERATING MANUAL VANE ANEMOMETER ...

Page 2: ...s store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warnings and instructions for future reference This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory...

Page 3: ...device is not a toy and does not belong in the hands of children Warning Dangers can occur at the device when it is used by untrained people in an unprofessional or improper way Observe the personnel qualifications Caution Keep a sufficient distance from heat sources Note To prevent damages to the device do not expose it to extreme temperatures extreme humidity or moisture Note Do not use abrasive...

Page 4: ...30 m s 3 40 ft min 3 1 0 km h 3 0 4 mph 3 0 4 kn Measuring range resolution 0 01 m s 1 ft min 0 1 km h 0 1 mph 0 1 kn General technical data Measuring rate approx 1 measurement per second Display LCD monochrome Maximum operating altitude 2000 m Storage temperature 10 C to 60 C 14 F to 140 F with 80 RH non condensing Operating temperature 0 C to 50 C 32 F to 122 F with 80 RH non condensing Power su...

Page 5: ... device is dry and the device is switched off 4 13 1 Remove the battery compartment cover 4 from the device 2 Use the battery clip 13 to connect the new battery with correct polarity 3 Slide the battery compartment cover 4 back on the device Switch on and measurements 1 Press the power button 7 ð The display will be switched on and the device ready for operation 2 Hold the sensor 1 into the area w...

Page 6: ...tact the manufacturer Errors and faults The device has been checked for proper functioning several times during production If malfunctions occur nonetheless check the device according to the following list Fault Cause Remedy The device can no longer be switched on The battery is dead Insert a new battery see chapter Operation Disposal The icon with the crossed out waste bin on waste electrical or ...

Page 7: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: