3. Press the
PROG
button (8) to adjust the minutes.
ð
The minute indication flashes on the display.
4. Press the
RESET (+)
button (9) or the
START/
STOP (-)
button (10) to increase or decrease the number of
minutes.
5. Press the
PROG
button (8) to set the number of seconds.
6. Press the
RESET (+)
button (9) or the
START/
STOP (-)
button (10) to increase or decrease the number of
seconds.
7. If you press the
PROG
button (8) again, the timer switches
back to the timer mode.
8. If you press the
START/STOP (-)
button (10) afterwards, the
timer starts running.
ð
The timer is activated.
ð
The display indication is minimised and a bell symbol
flashes on the display.
ð
The ozone generation starts after one minute.
ð
Once the set time on the timer has expired, 2 signal
sounds will be emitted. The previously set time is
shown on the display indication.
9. If you press the
START/STOP (-)
button (10) while the timer
is running, the timer will stop prematurely.
10. Press the
RESET (+)
button (9) to set the timer back to the
previously set time.
Info
If you press the
START/STOP (-)
button (10) if the timer
indication is 00:00 00, the bell symbol will flash on the
display. The timer remains deactivated until you press
the
START/STOP (-)
button (10) again.
Resetting the timer
You can reset the timer by simultaneously and briefly pressing
the
PROG
(8),
RESET (+)
(9) and
START/STOP (-)
(10) buttons.
The timer will switch back to 00:00:00.
System reset timer
You can carry out a system reset by simultaneously and briefly
pressing the
PROG
(8),
RESET (+)
(9) and
START/
STOP (-)
(10) buttons for 3 seconds.
Recording of the operating time
The operating hours counter (2) indicates the duration the
device has already been in operation.
The number of elapsed operating hours can be used for the
calculation of the energy consumption. Use the following
formula:
0.11 kW/h x operating hours.
The result will be no more than an approximate value of the
average consumption. For the precise determination of the
current consumption you can additionally install an ammeter
between device and energy source.
Carrying out an odour neutralization / air purification
Warning
Risk of injury caused by inhalation of ozone!
The following symptoms could be indicative of
poisoning or an irritation caused by ozone:
- eye irritations – conjunctivitis, stinging and watering
eyes
- strong urge to cough
- shortness of breath – chest tightness
- pain while inhaling
- dizziness, light-headedness
- headache
- feeling of faintness
Exit the room to be cleaned immediately after the
device has been switched on.
Do not enter the room whilst the air purification is in
progress.
Should you experience one or more of the above
symptoms relating to the use of the odour neutraliser,
seek medical treatment immediately!
Please proceed as follows to perform an air purification:
1. Seal off all openings of the room to be cleaned. It must be
accomplished in a way to prevent ozone from escaping to
the environment.
2. Attach warnings that indicate the presence of high ozone
concentrations and the related hazards.
3. Make sure that neither humans nor animals are situated in
the room to be cleaned.
4. Position the device in the centre of the room.
5. Connect the power cable and insert the mains plug into a
properly secured mains socket located outside of the room
to be cleaned.
6. Set the desired treatment duration by means of the timer.
7. Switch the device on by pressing the
on/off
button (6).
ð
Air purification will commence immediately.
8. Exit the room directly after having started the device.
ð
The ozone generator will now operate until the end of
the set cleaning period. Afterwards it will switch off
automatically.