air cleaner AirgoClean® 350 E

6. Reinsert the air inlet with the prefilter (

4

) into the device.

4

Technical annex

Technical data

Parameter

Value

Model

AirgoClean

®

 350 E

Air flow rate with 
HEPA carbon filter
Fan stage 

I

Fan stage 

II

Fan stage 

III

Turbo mode

260 m

3

/h

450 m

3

/h

650 m

3

/h

1000 m

3

/h

Ambient temperature

0 °C to 35 °C

Operating range

0 % to 95 % RH

Mains connection

220–240 V / 50–60 Hz

Power consumption

105 W

Nominal current

0.46 A

Sound pressure level
(1 m distance)

60.5 dB(A)

Dimensions 
(length x width x height)

390 x 405 x 795 mm

Minimum distance to
walls and other objects

A: top

B: rear

C: side

D: front

30 cm
30 cm
30 cm
30 cm

Weight

14 kg

Disposal

The icon with the crossed-out waste bin on waste

electrical or electronic equipment stipulates that this equipment
must not be disposed of with the household waste at the end of
its life. You will find collection points for free return of waste
electrical and electronic equipment in your vicinity. The
addresses can be obtained from your municipality or local
administration. You can also find out about other return options
that apply for many EU countries on the website 
https://hub.trotec.com/?id=45090. Otherwise, please contact an
official recycling centre for electronic and electrical equipment
authorised for your country.
The separate collection of waste electrical and electronic
equipment aims to enable the re-use, recycling and other forms
of recovery of waste equipment as well as to prevent negative
effects for the environment and human health caused by the
disposal of hazardous substances potentially contained in the
equipment.

In the European Union, batteries and accumulators must not be
treated as domestic waste, but must be disposed of
professionally in accordance with Directive 2006/66/EC of the
European Parliament and of the Council of 6 September 2006
on batteries and accumulators. Please dispose of batteries and
accumulators according to the relevant legal requirements.

Summary of Contents for AIRGOCLEAN 350E E

Page 1: ...TRT BA AIRGOCLEAN 350E TC2021 21 001 EN AIRGOCLEAN 350 E EN OPERATING MANUAL AIR CLEANER...

Page 2: ...he manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock...

Page 3: ...cated in the immediate surroundings of air inlet and air outlet Do not remove any safety signs stickers or labels from the device Keep all safety signs stickers and labels in legible condition Do not...

Page 4: ...ight and medium contaminations and odours in order to improve the air quality It is equipped with a powerful fan sucking in the air The air flows through the filter and is cleaned Afterwards the fan r...

Page 5: ...make the device easier to transport it is fitted with wheels Before transporting the device observe the following Switch the device off Hold onto the mains plug while pulling the power cable out of t...

Page 6: ...chapter Technical annex A B C C D Before restarting the device check the condition of the power cable If there are doubts as to the sound condition contact the customer service Only put up the device...

Page 7: ...eed button For setting the fan speed 21 Auto button Switching the automatic mode on or off 22 PM2 5 Timer indication Indication of the particulate matter pollution in g m3 or the number of hours of th...

Page 8: ...ated in blue good air quality 51 100 Illuminated in red medium air quality 100 Please proceed as follows to switch off the automatic mode 1 Press the Auto button 21 The Auto LED 16 goes out The symbol...

Page 9: ...peed air quality LEDs 25 are illuminated according to the selected fan stage 3 Press the ionizer button 29 again to deactivate the ionization function The Ionizer LED 10 goes out Setting the timer The...

Page 10: ...eplace the HEPA carbon filters The prefilter is soiled and has to be cleaned Clean the prefilter see chapter Operation and maintenance The air outlets are obstructed Make sure that the air outlets are...

Page 11: ...tachment screws X X Test run X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign...

Page 12: ...ir filters 2 Use a torch to illuminate the openings of the device 3 Check the inside of the device for dirt 4 If you see a thick layer of dust clean the inside of the device with a vacuum cleaner 5 Re...

Page 13: ...ut of the device 35 36 3 Dispose of the HEPA carbon filter according to the national regulations 4 Take the new HEPA carbon filter out of the plastic cover 5 Insert the new HEPA carbon filter 35 into...

Page 14: ...the prefilter 4 from the device by pressing Push 4 2 Remove the prefilter 37 from the air inlet 4 4 37 3 Clean the filter using a slightly damp soft lint free cloth If the filter is heavily contaminat...

Page 15: ...for free return of waste electrical and electronic equipment in your vicinity The addresses can be obtained from your municipality or local administration You can also find out about other return opt...

Page 16: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: