Trotec AIRGOCLEAN 250 E Operating Manual Download Page 8

8

EN

air cleaner AirgoClean® 250 E

Setting the operating mode

The device comes with the following operating modes:

• Automatic mode
• Night mode
• Turbo mode
• Ventilation

Automatic mode

When in automatic mode, the device automatically detects the
air quality.
Please proceed as follows to set the automatic mode:

ü

The device is switched on.

1. Press the 

Mode

 button (

15

) until the 

Auto

 LED (

13

) is

displayed.

ð

The device is now running in automatic mode.

If the device is in automatic mode while it is getting dark, the
light detection function will react and automatically put the
device into night mode.
When the brightness increases, the display illumination will also
increase and the fan speed will return to the level last set.
The 

Air quality fine dust value

 LED (

18

) or the 

Air quality

gaseous pollutants

 LED (

19

) is illuminated.

Air quality: 

fine dust value

Air quality 

fine dust value

LED

Fine dust value

indication (PM2.5 value)

Illuminated in blue
(very good air quality)

0-55

Illuminated in green
(good air quality)

56-100

Illuminated in orange
(medium air quality)

101-150

Illuminated in red
(poor air quality)

>150

Air quality: 

gaseous pollutants

Air quality 

gaseous pollutants

 LED

Illuminated in blue (very good air quality)
Illuminated in green (good air quality)
Illuminated in orange (medium air quality)
Illuminated in red (poor air quality)

Please proceed as follows to switch off the automatic mode:

1. Press the 

Mode

 button (

15

) until the 

Auto

 LED (

13

) goes

out.

ð

The device switches over to the next operating mode.

Info
Automatic mode and virus filtration

Do not use the automatic mode if the device is used for
virus filtration!
The integrated sensors only respond to air pollution
caused by fine particulates, pollen or possibly VOC
(organic chemical compounds). The device cannot
determine the virus load inside the room. It is possible
that the automatic mode indicates a "good air quality"
even though the virus load in the room is very high.
Therefore, when using the device for virus filtration, we
recommend that you always select a fixed performance
level adapted to the room size or the required
circulation rate.

Night mode

Info

In night mode, the ionization function cannot be added.

In night mode, the control panel is dimmed and the device
generates an air current that is adapted to your sleep habits.
Proceed as follows to switch on night mode:

ü

The device is switched on.

1. Press the 

Mode

 button (

15

) until the 

Sleep

 LED (

13

) is

displayed.

ð

The 

Sleep

 LED (

13

) is illuminated.

2. Press the 

Mode

 button (

15

) again to switch off the night

mode.

Turbo mode

Note

In turbo mode, the room air is automatically disinfected
by means of negative ions. This additional function is
only available with activated turbo mode.

In 

turbo

 mode, the fan runs at the highest fan speed.

ü

The device is switched on.

1. Press the 

Mode

 button (

15

) until the 

Turbo

 LED (

13

) is

illuminated.

2. Press the 

Mode

 button (

15

) again to switch off the turbo

mode.

Ventilation

In 

ventilation

 mode, you can select all fan speeds manually.

Please proceed as follows to select the fan stages:

ü

The device is switched on.

1. Select the desired speed by pressing the

speed

 button (

16

).

ð

The 

Speed

 LED (

12

) of stage 1, 2 or 3 is illuminated.

ð

Each time the buttons are operated, an acoustic signal
is emitted.

Summary of Contents for AIRGOCLEAN 250 E

Page 1: ...TRT BA AIRGOCLEAN 250E TC2020 54 002 EN AIRGOCLEAN 250 E EN OPERATING MANUAL AIR CLEANER...

Page 2: ...e manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock f...

Page 3: ...e objects Dispose of replaced filters properly especially after filtering substances hazardous to health e g asbestos or spray paint mists Never use the device as storage place or footstep Never selec...

Page 4: ...carbon filter and a separate prefilter on each side The device uses the HEPA filters to remove bacteria viruses pollen dust mite residue mould fungus spores and other allergens from the air The integ...

Page 5: ...it is fitted with a carry handle To make the device easier to transport it is fitted with wheels Before transporting the device observe the following Switch the device off Hold onto the mains plug whi...

Page 6: ...ects as described in the chapter Technical data A B C C D Before restarting the device check the condition of the power cable If there are doubts as to the sound condition contact the customer service...

Page 7: ...e indica tion LED Indication of the pollution with particulate matter 18 Air quality fine dust value LED Illuminated according to the measured air quality blue very good green good orange medium red p...

Page 8: ...c mode and virus filtration Do not use the automatic mode if the device is used for virus filtration The integrated sensors only respond to air pollution caused by fine particulates pollen or possibly...

Page 9: ...ction The Ionizer LED 11 is illuminated The device starts to filter the room air 2 Press the Ionization button 10 again to deactivate the plasma function The Ionizer LED 11 goes out Illumination You c...

Page 10: ...s with no capacity or the air quality does not improve Check whether any windows and or doors of the room are open If so close them The HEPA carbon filter is not installed Install the HEPA carbon filt...

Page 11: ...tachment screws X X Test run X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign...

Page 12: ...nters the housing Protect electrical components from moisture Do not use any aggressive cleaning agents such as cleaning sprays solvents alcohol based or abrasive cleaners to dampen the cloth Note Cle...

Page 13: ...aults Make sure that the HEPA carbon filters and the prefilters are installed before switching the device on Without the HEPA carbon filters and the prefilters the device cannot fulfil its air cleaner...

Page 14: ...26 25 7 Reinsert the prefilter 24 into the device 24 8 Put the air inlet 3 back on the device 3 9 Press the Ionizer button 10 for 3 seconds to reset the HEPA carbon filter or prefilter Cleaning the pr...

Page 15: ...ection 220 240 V 50 Hz Power consumption 45 W Nominal current 0 17 A Sound pressure level at a distance of 1 m 56 dB A Dimensions length x width x height 360 x 360 x 710 mm Minimum distance to walls a...

Page 16: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: