air cleaner AirgoClean® 170 E

Info
Automatic mode and virus filtration

Do not use the automatic mode if the device is used for
virus filtration!
The integrated sensors only respond to air pollution
caused by fine particulates, pollen or possibly VOC
(organic chemical compounds). The device cannot
determine the virus load inside the room. It is possible
that the automatic mode indicates a "good air quality"
even though the virus load in the room is very high.
Therefore, when using the device for virus filtration, we
recommend that you always select a fixed performance
level adapted to the room size or the required
circulation rate.

Night mode

In 

night

 mode, the device generates an air current that is

adapted to your sleep habits.
Proceed as follows to switch on night mode:

ü

Measuring the air quality is not activated and the 

air

quality

 LED (

8

) is not illuminated.

1. Press the 

operating mode

 button (

9

).

ð

The device is running at the lowest fan stage. The 

fan

speed

 LED (

12

) is not illuminated.

ð

The 

night mode

 LED (

6

) is illuminated.

If no operational input is made for approx. 40 seconds, the
brightness of the control panel decreases.

Turbo mode

When in turbo mode, the device automatically detects the air
quality. The 

air quality

 LED (

8

) is illuminated and the air quality

is indicated on the segment display (

7

).

Proceed as follows to switch on turbo mode:

1. Press the 

operating mode

 button (

9

).

ð

The device is running at the highest fan stage.

ð

The 

fan speed

 LED (

12

) is illuminated.

Ventilation

In this mode you can select all 5 speeds manually.
Please proceed as follows to adjust the fan speed:

ü

The device is switched on.

1. Select the desired fan speed by pressing the 

fan

speed

 button (

11

).

ð

The 

fan speed

 LED (

12

) of stage 1, 2, 3, 4 or 5 is

illuminated.

Memory function

If you switch the device back on from standby mode, the
settings selected for the operating mode and fan speed are
saved.
In the event of brief power failures or if the cover is opened, the
device will 

not

 remember the settings. When switched on, the

device will start in 

automatic

 mode in this case.

Shutdown

Warning of electrical voltage

Do not touch the mains plug with wet or damp hands.

Switch off the device by pressing the 

Power

 button (

10

).

Hold onto the mains plug while pulling the power cable out
of the mains socket.

Clean the device according to the Maintenance chapter.

Store the device according to the Storage chapter.

Available accessories

Warning

Only use accessories and additional equipment
specified in the operating manual.
Using insertion tools or accessories other than those
specified in the operating manual may cause a risk of
injury.

Designation

Article number

HEPA carbon filter, filter class E12

7.160.000.530

Summary of Contents for AIRGOCLEAN 170 E

Page 1: ...TRT BA AIRGOCLEAN 170E TC2020 48 001 EN AIRGOCLEAN 170 E EN OPERATING MANUAL AIR CLEANER...

Page 2: ...manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fi...

Page 3: ...lters properly especially after filtering substances hazardous to health e g asbestos or spray paint mists Never use the device as storage place or footstep Never select automatic mode if the device i...

Page 4: ...fan releases the clean air back into the room The 3 in 1 filter is composed of a HEPA filter a carbon filter and a prefilter The device uses a HEPA filter to remove bacteria viruses pollen dust mite...

Page 5: ...cable is not damaged and that you do not damage it during unwinding Start up The HEPA carbon filter is pre installed Note Remove the plastic cover from the HEPA carbon filter To do so please proceed...

Page 6: ...automatic mode The corresponding operating mode LED 6 will be illuminated The device measures the air quality within 3 minutes The air quality LED 8 is illuminated The air quality will be indicated on...

Page 7: ...nated and the air quality is indicated on the segment display 7 Proceed as follows to switch on turbo mode 1 Press the operating mode button 9 The device is running at the highest fan stage The fan sp...

Page 8: ...re open If so close them The HEPA carbon filter is not installed Install the HEPA carbon filter Check the minimum distance to walls or other objects Position the device a little more in the room s cen...

Page 9: ...t screws X X Test run X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign object...

Page 10: ...emove the air filter 2 Use a torch to illuminate the openings of the device 3 Check the inside of the device for dirt 4 If you see a thick layer of dust clean the inside of the device with a vacuum cl...

Page 11: ...ng The operating life of the HEPA carbon filter is approx 6 months depending on the degree of air pollution If required visually inspect the HEPA carbon filter for dirt 1 Remove the rear device cover...

Page 12: ...stage 3 Fan stage 4 Fan stage 5 123 m3 h 195 m3 h 263 m3 h 320 m3 h 350 m3 h Ambient temperature 5 C to 40 C Operating range 30 to 90 RH Mains connection 220 240 V 50 60 Hz Power consumption 25 W Nom...

Page 13: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: