Info
Automatic mode and virus filtration
Do not use the automatic mode if the device is used for
virus filtration!
The integrated sensors only respond to air pollution
caused by fine particulates, pollen or possibly VOC
(organic chemical compounds). The device cannot
determine the virus load inside the room. It is possible
that the automatic mode indicates a "good air quality"
even though the virus load in the room is very high.
Therefore, when using the device for virus filtration, we
recommend that you always select a fixed performance
level adapted to the room size or the required
circulation rate.
Night mode
In
night
mode, the device generates an air current that is
adapted to your sleep habits.
Proceed as follows to switch on night mode:
ü
Measuring the air quality is not activated and the
air
quality
LED (
8
) is not illuminated.
1. Press the
operating mode
button (
9
).
ð
The device is running at the lowest fan stage. The
fan
speed
LED (
12
) is not illuminated.
ð
The
night mode
LED (
6
) is illuminated.
If no operational input is made for approx. 40 seconds, the
brightness of the control panel decreases.
Turbo mode
When in turbo mode, the device automatically detects the air
quality. The
air quality
LED (
8
) is illuminated and the air quality
is indicated on the segment display (
7
).
Proceed as follows to switch on turbo mode:
1. Press the
operating mode
button (
9
).
ð
The device is running at the highest fan stage.
ð
The
fan speed
LED (
12
) is illuminated.
Ventilation
In this mode you can select all 5 speeds manually.
Please proceed as follows to adjust the fan speed:
ü
The device is switched on.
1. Select the desired fan speed by pressing the
fan
speed
button (
11
).
ð
The
fan speed
LED (
12
) of stage 1, 2, 3, 4 or 5 is
illuminated.
Memory function
If you switch the device back on from standby mode, the
settings selected for the operating mode and fan speed are
saved.
In the event of brief power failures or if the cover is opened, the
device will
not
remember the settings. When switched on, the
device will start in
automatic
mode in this case.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
•
Switch off the device by pressing the
Power
button (
10
).
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
•
Clean the device according to the Maintenance chapter.
•
Store the device according to the Storage chapter.
Available accessories
Warning
Only use accessories and additional equipment
specified in the operating manual.
Using insertion tools or accessories other than those
specified in the operating manual may cause a risk of
injury.
Designation
Article number
HEPA carbon filter, filter class E12
7.160.000.530