Trotec AIRGOCLEAN 170 E Operating Manual Download Page 6

6

EN

air cleaner AirgoClean® 170 E

Operation

Note

Avoid open doors and windows.

Control panel

13

11

10

9

7

8

6

12

No.

Designation

Meaning

6

Operating mode

 LEDs

Indicates the selected
operating mode:

automatic mode

night mode

turbo mode

7

Segment display

Indicates the measured air
quality

8

Air quality

 LED

Is illuminated according to
the air quality:
green = good
blue = medium
red = poor

9

Operating mode

 button

Selecting the operating
mode

10

Power

 button

For switching the device on
and off

11

Fan speed

 button

Setting the fan speed in
5 stages

12

Fan speed

 LED

Indication of the selected
fan speed

13

Filter change

 LED

Illuminated when the filter
needs to be changed

Switching the device on

Once you have completely installed the device as described in
the Start-up chapter, you can switch it on. When the power
cable has been connected, the control panel lights up for
2 seconds and an acoustic signal is emitted. Afterwards, only
the 

Power

 button (

10

) is illuminated in red and the device is in

standby mode.
Please proceed as follows to switch the device on:

1. Press the 

Power

 button (

10

).

ð

The 

Power

 button (

10

) is illuminated in white.

ð

The device is switched on and starts operating in
automatic mode. The corresponding operating
mode LED (

6

) will be illuminated.

ð

The device measures the air quality within 3 minutes.
The 

air quality

 LED (

8

) is illuminated. The air quality will

be indicated on the segment display (

7

).

If no operational input is made for approx. 40 seconds, the
brightness of the control panel decreases. The full brightness
will be restored the next time you make an entry.

Setting the operating mode

The device comes with the following operating modes:

Automatic mode

Night mode

Turbo mode

Please proceed as follows to switch between operating modes:

ü

The device is switched on.

1. Press the 

operating mode

 button (

9

).

ð

The corresponding 

operating mode

 LED (

6

) will be

illuminated.

Automatic mode

Once you switch on the device, it starts in automatic mode. The
corresponding 

operating mode

 LED (

6

) will be illuminated.

When in automatic mode, the device automatically detects the
air quality.
The 

air quality

 LED (

8

) is illuminated accordingly in green, blue

or red. The air quality will be indicated on the segment
display (

7

).

The PM2.5 value will be indicated on the segment display (

7

)

after the device has carried out the air quality measurement.

Air quality

 LED Indication on the

segment display

Fan speed

LED

Illuminated in
green
(good air quality)

0 ~ 35

Stage 2

Illuminated in
blue
(medium air
quality)

36 ~ 116

Stage 3 and 4

Illuminated in red
(poor air quality)

> 116

Stage 4 and 5

Summary of Contents for AIRGOCLEAN 170 E

Page 1: ...TRT BA AIRGOCLEAN 170E TC2020 48 001 EN AIRGOCLEAN 170 E EN OPERATING MANUAL AIR CLEANER...

Page 2: ...manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fi...

Page 3: ...lters properly especially after filtering substances hazardous to health e g asbestos or spray paint mists Never use the device as storage place or footstep Never select automatic mode if the device i...

Page 4: ...fan releases the clean air back into the room The 3 in 1 filter is composed of a HEPA filter a carbon filter and a prefilter The device uses a HEPA filter to remove bacteria viruses pollen dust mite...

Page 5: ...cable is not damaged and that you do not damage it during unwinding Start up The HEPA carbon filter is pre installed Note Remove the plastic cover from the HEPA carbon filter To do so please proceed...

Page 6: ...automatic mode The corresponding operating mode LED 6 will be illuminated The device measures the air quality within 3 minutes The air quality LED 8 is illuminated The air quality will be indicated on...

Page 7: ...nated and the air quality is indicated on the segment display 7 Proceed as follows to switch on turbo mode 1 Press the operating mode button 9 The device is running at the highest fan stage The fan sp...

Page 8: ...re open If so close them The HEPA carbon filter is not installed Install the HEPA carbon filter Check the minimum distance to walls or other objects Position the device a little more in the room s cen...

Page 9: ...t screws X X Test run X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign object...

Page 10: ...emove the air filter 2 Use a torch to illuminate the openings of the device 3 Check the inside of the device for dirt 4 If you see a thick layer of dust clean the inside of the device with a vacuum cl...

Page 11: ...ng The operating life of the HEPA carbon filter is approx 6 months depending on the degree of air pollution If required visually inspect the HEPA carbon filter for dirt 1 Remove the rear device cover...

Page 12: ...stage 3 Fan stage 4 Fan stage 5 123 m3 h 195 m3 h 263 m3 h 320 m3 h 350 m3 h Ambient temperature 5 C to 40 C Operating range 30 to 90 RH Mains connection 220 240 V 50 60 Hz Power consumption 25 W Nom...

Page 13: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: