14
EN
oil heater IDE 20 / IDE 30 / IDE 50 / IDE 60 / IDE 80
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Note
Damage to the device due to overheating!
Never switch off the device by pulling the mains plug.
This may lead to overheating!
Switch off the device properly. Only remove the mains
plug from the device once the fan motor has stopped
completely.
IDE 20
1. Turn the rotary control thermostat (15) to minimum.
2. If necessary, regulate the external thermostat to a low
temperature using the settings of the controller.
3. Wait for approx. 90 s until the fan motor has come to a
complete standstill.
4. Switch the device off by setting the on/off switch (18) to
position
0
.
ð
The on/off switch (18) is no longer illuminated.
5. Secure the device against inadvertent switch-on by pulling
the mains plug.
6. Allow the device to cool down completely.
IDE 30 / IDE 50 / IDE 60 / IDE 80
1. Switch the device off by setting the on/off switch (18) to
position
0
.
ð
The flame goes out and the fan continues to run for
approx. 90 seconds in order to cool down the burner.
2. If you use a thermostat, switch off the device using the
settings of the controller (e.g. by setting a lower
temperature at the thermostat).
3. Wait for approx. 90 s until the fan motor has come to a
complete standstill.
4. Secure the device against inadvertent switch-on by pulling
the mains plug.
5. Allow the device to cool down completely.
Restart after troubleshooting
During initial start-up and after the fuel oil circuit has been
drained completely, the fuel oil supply to the nozzle may be
insufficient. In this case, the flame monitoring system will
respond and the device will be blocked. Proceed as follows:
1. Wait for approx. 1 minute.
2. Switch the device on.
If the device is still not starting, proceed as follows:
1. Make sure that there is fuel left in the tank.
2. Please refer to the chapters General safety warnings and
Errors and faults.