convector TCH 25 E / TCH 26 E
The air current is reduced:
•
Check the air inlet and outlet. Make sure that air inlet and
outlet are not obstructed. Remove any dirt. Observe the
minimum distance from walls or other objects according to
the technical data.
Note
Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.
The device still does not operate correctly after these
checks:
Please contact the customer service. If necessary, bring the
device to an authorised specialist electrical company or to
Trotec for repair.
Maintenance
Activities required before starting maintenance
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
•
Switch the device off.
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
•
Allow the device to cool down completely.
Warning of electrical voltage
Tasks which require the device to be opened must
only be carried out by authorised specialist
companies or by Trotec.
Cleaning the housing
Warning of electrical voltage
Never immerse the device in water!
Clean the housing with a soft, damp and lint-free cloth. Make
sure that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth.
Wipe the housing dry after cleaning.
Technical annex
Technical data
Parameter
Value
Model
TCH 25 E /
TCH 26 E
Heating capacity
level 1:
level 2:
level 3:
750 W
1250 W
2000 W
Mains connection
220 – 240 V /
50 / 60 Hz
Power consumption max. 2000 W
Nominal current
consumption
8.7 A
Fusing
10 A
Cable length
1.5 m
Plug type
CEE 7/7
Type of protection
IPX0
Dimensions (depth x width
x height)
100 x 600 x 360 mm
Minimum distance to walls
and other objects
top (A):
rear (B):
sides (C):
front (D):
100 cm
50 cm
50 cm
50 cm
Weight
3.5 kg