Ozone generator Airozon® 28 ECO
Switch-off
Warning
Risk of injury caused by ozone!
Have especially trained staff check the ozone
concentration before entering the room and permitting
others to access it.
Warning
Wear a respirator mask with ozone filter when you
check whether the ozone concentration has decreased
sufficiently by means of a suitable measuring device.
The device was designed to switch off automatically once the
set time has elapsed. A corresponding function was integrated
by way of a timer.
A certain waiting period must be observed between the device
switch-off and accessing the treated room.
At the end of the waiting period the room must be aired out
extensively. Open doors and windows. Take the corresponding
protective measures (see Safety chapter).
Info
Within this safety period the remaining ozone
decomposes (naturally) into divalent oxygen (O
2
).
Afterwards the ozone concentration should have fallen
to below the stipulated MAC value (maximum allowable
concentration) of 0.2 mg/m³. Ozone has an average
half-life of approx. 30 min to 60 min. The half-life
depends on various factors, e.g. on the surface to be
treated in the respective room, the temperature and
the relative humidity.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
1. Switch off the device by pressing the
Power
button (19).
ð
Once you have switched the device off, the fan and one
of the ozone plates inside the device will keep working
for another minute in order to cool the device.
2. Hold onto the mains plug while pulling the power cable out
of the mains socket.
3. Clean the device according to the Maintenance chapter.
4. Store the device according to the Storage chapter.
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
•
Check the power connection.
•
Check the power cable and mains plug for damage.
•
Check the on-site fusing.
•
Switch the fuse back on or have a defective fuse replaced
by a specialist company.
•
Wait for 10 minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.
The device is very loud:
•
Position the device on a dry, firm and level surface.
•
Check whether the fan and its bearing for damage. If you
detect any damage, have the device checked by a certified
specialist workshop.
The odour nuisance persists after the completed
purification process with the same intensity:
•
Have the device checked by a certified specialist
workshop.
The device still does not operate correctly after these
checks:
Please contact the customer service. If necessary, bring the
device to an authorised specialist electrical company or to
Trotec for repair.