EN
9
condenser dryer DH 95 S
The duration of the defrost process can vary. Do
not
switch off
the device during automatic defrost. Do
not
remove the mains
plug from the mains socket.
•
Automatic defrosting is interrupted once you actuate the
ON/OFF
button (15) or either the
increase value
button (9)
or the
decrease value
button (18).
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
•
Switch off the device.
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
•
If necessary, remove the condensation drain hose and any
residual fluid from it.
•
Clean the device according to the Maintenance chapter.
•
Store the device according to the Storage chapter.
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
Note
The device is equipped with a safety timer.
Switch-ons and switch-offs can be delayed by up to
3 minutes.
The device does not start:
•
Check the power connection.
•
Check the power cable for damages.
•
Check the on-site fusing.
•
Check the filling level of the condensation tray and empty
it, if necessary. The indicator light for the condensation
tray (2) must not be illuminated and the buzzer must not
emit an acoustic signal.
•
Have the electrics checked by a specialist company for
cooling and air-conditioning or by Trotec.
The device is running, but there is no formation of
condensate:
•
Check whether the condensation drain hose is positioned
correctly.
•
Check the room temperature. Observe the device's
permissible operating range according to the technical
data.
•
Ensure that the relative humidity complies with the
technical data.
•
Check the preselected desired humidity level. The humidity
in the room where the device is positioned must be at least
3 % higher than the target value. If necessary, reduce the
set relative humidity.
•
Check the condensate pump for proper functioning or
unusual vibrations and sounds. Remove external dirt (see
chapter Maintenance).
•
Check both air filters for dirt. If necessary, clean or replace
the air filters (see chapter Maintenance).
•
Check the exterior of the condenser and the condensate
pump for dirt (see chapter Maintenance). If the inside of
the device is dirty, have it cleaned by a specialist company
or by Trotec.
The device is loud or vibrates:
•
Check whether the device is set up in a stable and upright
position.
The device gets very warm, is loud or loses power:
•
Check the air inlets and air filters for dirt. Remove external
dirt.
•
Check the inside of the device and especially the fan, the
fan housing, the evaporator, the condenser and the
condensate pump for external dirt (see chapter
Maintenance). If the inside of the device is dirty, have it
cleaned by a specialist company for cooling and
air-conditioning or by Trotec.
Your device still does not operate correctly after these
checks?
Please contact the customer service. If necessary, bring the
device to a specialist company for cooling and air-conditioning
or to Trotec for repair.
Error codes
The following error messages can be displayed on the segment
display:
Error code Cause
Remedy
E1
Refrigerant filling
level too low
Please contact the
customer service.
E2
Error message of the
temperature sensor
Switch the device off and
contact the customer
service.
E3
Error message of the
humidity sensor
Use the drying unit at a
humidity level which
complies with the technical
data.
E5
Error message of the
sensor in the
refrigerant circuit
Switch the device off and
contact the customer
service.